The incident occurred at the hydrocracker unit, which was being shut down for maintenance and the reactor was in a hydrogen purge cycle. A hydrogen gas line failed at a weld. The line was at 3000 psi…

The incident occurred at a hydrogenation reactor producing alcohols. At the time of the fault, the plant was in normal operation. A sudden leak of hydrogen occurred on the flange of the upper…

A hydrogen leak occurred on the hydrogen line of a hydro-desulphurisation unit, followed by ignition . The failure was located on a supply manifold of the unit at a support beam. The unit was shut…
Three workers were working in the sulphur recovery unit (SRU), trying to restore the hydrogen flow. The workers were trying to isolate the cause of a flow problem: hydrogen was entering the…
The regular maintenance of the hydrogen production equipment had been completed and the plant was about to start up. At this point, fluid mainly composed of hydrogen was sent via a pipe to the…
The fire occurred on a flange of a hydrogen supply line to a desulfurization reactor unit of diesel, which leaked and ignited (30 cm flame) The leak was stopped by isolating the part of line affected…
A hot oil line (8-inch) in the hydro-desulphurisation (HDS) unit failed due to fatigue cracking. Hot oil at 50 bar and 343°C sprayed across the roadway into the hydrogen units where ignition occurred…

A hydrogen fire broke out at the aft end of the orbiter connected to the LH2 onboard tank of a space shuttle. This happened during the abortion of the launch, occurred due to another cause, the…

A truck transporting hydrogen and oxygen cylinders collided with a passenger vehicle at an intersection and overturned, causing all cylinders containers to fall onto the road. Gas leaked from four…

After the filled hydrogen gas cylinders were unloaded onto the quay, the weather worsened and high waves caused the containers to break apart, and the cylinders were lost to the sea.

The release occurred on a pipeline inside a steam cracking unit located between two hydrogenation units. The gaseous mixture transported through this line (2" diameter, 30 bar, 40°C) was composed of…
The hydrogen leak occurred on a lorry travelling on a motorway. According to Highways England the vehicle was carrying nine cylinders of gas, one of which had a crack and was leaking. The only way to…

This incident occurred at a 70MPa hydrogen refuelling station. After completing a filling test, the pressure in the filling hose suddenly dropped. A worker heard the hissing sound of a hydrogen…

Following the first flight of the Montgolfier brothers, the first severe accident with hydrogen on a Montgolfier-balloon occurred in 1785, when trying to cross the Channel from France to England. Two…
The accident took place when replacing a pallet of empty hydrogen cylinders with a new full one. The pallet in service (almost empty) was not disconnected from the gas supply line. When the operator…
A fire broke out on the world’s first hydrogen carrier vessel shortly before setting sail from Australia to Japan carrying the world’s first international shipment of liquefied hydrogen. A flame was…
The station was storing 6,000 litres of liquid hydrogen in ten tanks. Rescue services were alerted and the station's activity is interrupted. The leak was stopped by closing the valves. According to…
A pallet containing 9 hydrogen cylinders was damaged during the operation of unloading the cylinders trailer by means of a forklift. A 2 mm wide crack, caused by the fork, was observed on a flexible.…

The burst disc activated prematurely on a small hydrogen tube trailer. The pressure at which the activation occurred was between 80 and 100 bar (1200 and 1500 psig). The design activation pressure…

The charge pump on a hydro-desulphuriser unit tripped. The charge flow control valve then opened wide on low flow. The high pressure hydrogen supply to the unit flowed backwards through a faulty non…