The incident occurred during maintenance works at a hydro-cracking unit of a refinery (the report does not explicitly mention the unit, but it is plausible to assume that it was a hydro-cracking…

A hydrogen leak in the hydrogen compressor unit of a filling station ignited causing the shut down of the whole station. The loss of containment was due the failure of a tie rod (diameter ~64mm) ,…

The event occurred at a liquid hydrogen spheric storage consisting of two large spheric vessels. A working team began a procedure to sample the LH2 storage vessels and the associated transfer pipe…

A fire in a leaking hydrogen unit at a 220,000-barrel oil sands plant temporarily cut production nearly 80 percent.
A rupture of a tube in the furnace of an oil refinery caused it to loose 700 pounds of diesel and hydrogen resulting in a fire. The fire burned for a half hour with 30- to 40-foot (10 to 12 m) flames…
This incident occurred at a reactor for the isomerization of wax in a lube oil plant. The high-pressure reactor ruptured during a catalyst activation operation. A hot (400 C) gaseous stream of…
Hydrogen was released into a diesel desulfurization unit, producing a 50-meter-long horizontal torch flame upon ignition. The unit was operating normally. Refinery firefighters responded quickly and…
The fire, 1 m high fire occurred in a pipe at the inlet of the hydrodesulphurisation unit of a refinery. The fire was caused by the leak of the pipe content, hydrogen and diesel fuel. According to…
The event occurred in an alkylation reactor. Due to the rupture of a pipe (probably due to material failure), a power failure took place and the plant was automatically put in hot-stand-by mode. This…
Follow a leak in a seal of a heat exchanger (metal-covered asbestos) a fire occurred in a reforming process. The hydrogen-rich mixture caused spontaneous inflammation. The fire lasted 30 minutes. The…
In a fertiliser plant, an ammonia synthesis unit stopped following the malfunction of an alternator due to a thunderstorm. The safety features were operating normally, yet the synthesis gas (N2 / H2)…
The accident occurred on the hopper fine powders from a pair of cyclones (the hopper is the bottom conical part of the cyclone collecting the powder/dust separated from gas phase). A bursting disc…
A fire broke out at a flange inside a heat exchanger of the catalytic reforming unit of a refinery. This heat exchanger had the purpose to pre-heat the load of heavy oil and hydrogen by recovering…
A fire occurred at the desulphurisation unit of a refinery during maintenance work. On the day of the incident, a distillation unit was shutdown for a steam air tightness test. A leak was found at…
The accident occurred in the de-sulphurisation unit, and specifically on a pipeline at 50 bar, for the recycling of the hydrogen (containing hydrogen sulphide impurities). The pipe failed due to…
In a hydro-desulphurisation unit of a refinery, a leak on a hydrogen line ignited and damaged the surrounding lines, including one with acid gas. The weather conditions (fog and very little wind)…
The event occurred on vent stack of an ammonia synthesis unit. The release of the gas was more specifically on the water purge line or the hydraulic guard of the vent stack. The process gas…
The fire occurred on the tube plate gaskets of 3 of the 4 exchangers loaded with catalytic reforming effluent. The fuel (500°C and p=30 bar) was a mixture of 30% hydrocarbons and 70% hydrogen. After…
As the airship approached the docking mast, it performed a sharp turn to face into the wind, which was shifting. The engines were run at full speed astern for about a minute to slow the airship. Dust…
A trailer-tractor transporting hydrogen cylinders veered off the road to the right at around for unclear reasons and eventually tipped over to the left. Part of the 4,000 cubic meters of hydrogen…