The explosion occurred in an incinerator for non-industrial wastes, during inspection and repair works. These were due to a large quantity of aluminium which produced a solid lump of ash. The…
At an agrochemical plant, an explosion occurred near a drained hydrofluoric acid tank, when 4 employees were welding on adjacent pipelines. An investigation was launched to determine this accident’s…
The incident occurred at a caustic soda electrolysis plant. A chlorine suction pump failed on a sodium hydroxide electrolysis unit. The arrest of the pump caused the stop of the electrolysis current.…
Static electricity ignited hydrogen in a rising advertising balloon.
Electric spark ignited hydrogen in a captive advertising balloon.
This incident occurred at an aromatics manufacturing plant. A staff member patrolling the plant heard a strange noise and rushed to the site, where he discovered a hole in a pipe, from which hydrogen…
The incident occurred at the recycle hydrogen compressor of a hydro-desulphurisation unit. The compressor was equipped with a suction rectifier. The drainpipe of this rectifier had been corroded…
A leakage and fire occurred during normal operation at a medium-pressure hydrocracker of a refinery. This unit perform a desulphurisation and a decomposition of heavy gas oil. High-temperature and…
When waste alkali solution was taken out of dumper trucks into a waste liquid storage tank, a reaction occurred in the tank. As a result, the solution in the tank foamed over it, and reached an…
The incident occurred at the direct desulfurization unit of heavy oil. A 130×90 mm oval opening occurred in the bypass pipe of the hydrogen sulphide absorption tower for the circulating gas, at a…
The explosion occurred during preparatory work to start a compressor that supplies hydrogen gas to a heavy oil direct desulfurization unit. The inspection cover of the crank case came off, injuring…
This incident occurred at CVD (coating vapour deposition) equipment. During operation, a vacuum pump for air discharging was turned on and by mistake silane and hydrogen gases were allowed to flow…
This incident occurred at a linear alkylbenzene manufacturing plant. It affected dehydrogenation reactor of normal paraffin, during the operation of catalyst exchange in the reactor. This is usually…
In a refinery, a fire occurred at a new reactor for the vacuum distillate hydro-desulphurisation unit. Process gas (hydrogen, hydrocarbon, etc. ) blew from a flange of upper piping in the reactor. It…
The event occurred at the flanges on the outlet of a desulphurization reactor, which was working under about 300 degrees C. The flanges and bolts were cooled down by a large amount of rainwater which…
A fire occurred at the desulphurisation unit of a refinery during maintenance work. On the day of the incident, a distillation unit was shutdown for a steam air tightness test. A leak was found at…
The incident occurred at a refinery unit for the desulphurisation of a light heavy oil. This unit was equipped with three hydrogen compressors. Two of them were usually operated and the third was…
An incident occurred on a compressor at a refinery Fluid Catalytic Cracker Unit (FCCU) plant involving hydrogen. Source of ignition was hot surface.
A weld on a 1 inch diameter instrument tapping from a Octafiner reactor overhead line fractured, resulting in a small but intense fire, lasting about 50 minutes until the unit was nitrogen purged.…
A triangle flask exploded during a science-class experiment where diluted hydrochloric acid was made to react with zinc to generate hydrogen, at a junior high school. Injures were caused by glass…