Rupture of Refinery Heat Exchanger
A petroleum refinery experienced a catastrophic rupture at one bank of three heat exchangers in a catalytic reformer/naphtha hydrotreater unit because of high temperature hydrogen attack (HTHA). Hydrogen and naphtha at more than 500F were released from the ruptured heat exchanger and ignited, causing an explosion and an intense fire burned for more than three hours.
The rupture fatally injured seven employees working in the immediate vicinity of heat exchanger at the time of the incident. The workers were in the final stages of a start-up activity to put a parallel bank of three heat exchangers back in service following cleaning. Such start-up activities had resulted in frequent leaks and occasional fires in the past and should have been considered as hazardous and nonroutine.
The damage of the specific heat exchanger was the result of its carbon steel being severly weakened by HTHA, a mechanism that results in fissures and cracking which occurs when the material is exposed to hydrogen at high temperatures and pressures, severely degarding the mechanical properties of the steel. API Recommended Practice 941 (Steels for Hydrogen Service at Elevated Temperatures and pressures in Petroleum Refnieries and Petrochemical Plants) provides Nelson curves to predict the occurrence of HTHA in various materials of construction. These curves are predicated on past equipment failure incidents and are plotted based upon self-reported process conditions. An investigative computer reconstruction of the ruptured heat exchanger estimated that exchanger was operating in a safe region of the Nelson curves where HTHA could not occur. API Recommended Practice 581 (Risk-Based Inspection Technology) allows users to calculate a damage factor to determine HTHA susceptibility of various materials of construction, rather than requiring users to actually verify operating conditions when determining applicable damage mechanisms.