Hydrogen Boosting Compressor Fails
A single-stage diaphragm compressor failed during boosting of high-pressure hydrogen ground storage banks. The compressor sources hydrogen from a 44 MPa storage bank as suction and discharges it at a stop set point of 85 MPa. The compressor capacity is 0.71 m3/min (25 scfm).
The original notice of failure was through an inter-diaphragm pressure indication and alarm. There should not be any pressure build-up between the layers of the diaphragm. Upon opening, hydraulic oil was found, leading to the assumption that the hydraulic-side diaphragm was leaking. Although spare diaphragms and seals were available for on-site repair, difficulty was encountered in attempting to remove the compressor nut above the diaphragms. Similar difficulties were encountered when the unit was returned to the manufacturer.
A new compressor nut of a different material was manufactured, plated, assembled to the head and returned for re-installation and operation. However, upon commissioning, it was discovered that the unit was not developing hydraulic pressure. The root cause was determined to be a fractured plunger, likely damaged during earlier repair efforts. The plunger was re-manufactured.