Hydrogen-Oxygen Balloon Hazards
An accident occurred during setup for a popular hydrogen-oxygen balloon science demonstration at a local public school. The demonstrator suffered painful second-degree burns to his right forearm and was taken to the hospital. The paramedics feared that grave respiratory damage (due to flame inhalation) might have occurred.
The demonstrator had transported 15 helium-quality balloons, pre-filled with a hydrogen-oxygen mixture, in a large, black, polyethylene garbage bag. During the setup, he opened the bag to remove a single balloon for stringing and floating. Without warning, the entire bag of balloons detonated violently. Fortunately, the incident occurred an hour prior to the program and no one else was near. It was also fortunate that only a small box caught fire and none of the other chemicals, already in place for other demonstrations, were involved.
Slow leakage of hydrogen from the balloons (since no balloon is capable of completely containing hydrogen) resulted in accumulation of hydrogen and oxygen inside the garbage bag. The dry, sealed bag created an environment ripe for the generation of static electricity. Simply touching the balloons ignited the leaking hydrogen and all 15 balloons.