HIAD Facility - Operational Condition: MAINTENANCE


The fire occurred in a unit to produce hexamethylenediamine, an organic compound precursor of polymers (HMD). The process is based on the hydrogenation of a precursor in presence of a catalyst. A jet…
First an explosion and then a fire occurred on the condensate piping of an chlorine electrolysis plant (SEVESO upper tiers). Flames escape from the end of the pipe and spill into a 75 m³ open sky…
A jet flame occurred in a diesel distillation unit. It was caused by the release and ignition of hydrogen from the low-pressure (60 bar) section of a the unit. It occurred during maintenance works…
Fire on a filter of an autoclave. The event occurred in a plant for the production of plastics. After catalytic synthesis of amines, the filter of the autoclave was taken out for cleaning. During the…
In a petrochemical plant, visual inspection detects fumes under the heat insulation of a heat exchanger operating under hydrogen pressure. The first intervention team was mobilized and the unit…
The event occurred during the disconnection of the hydrogen compressor for maintenance. Two deaths and three injured workers were the consequences. The cause(s) of the event are unknown .

This incident occurred a product purge vessel flange during planned maintenance activities on a chemical plant. The vessel had the function to collect unreacted gases from a polyethylene…

Three workers were asphyxiated when argon and hydrogen gas leaked from pipes they were installing on an aromatics plant being built on a cracking complex.

A hydrogen explosion occurred in a 5-tonne stainless steel pressure vessel, while two electro-polisher workers where electropolishing internal surfaces. The cause is believed to be the build-up…

Hydrogen explosion at a chlorine chemical production plant (Seveso-classified)The plant had been shut down for two weeks, and maintenance works were ongoing. Two subcontractor employees were cutting…
The explosion occurred while maintenance personnel were grinding a high-pressure injection (HPI) pipe, which had been recently cut at approximately 18 inches from the nozzle connecting the HPI pipe…
Hydrogen fire at a chlorine chemical production plant (Seveso-classified) Hydrogen ignited in a chlorine electrolyser unit. The facility was shutdown when the incident occured. The staff of the unit,…
The fire occurred after a hydrogen released from a venting valve opened for inspection. The hydrogen was at 300 bar and 300C centigrade and between 200 and 300 bar. The hydrogen ignited probably…
A hydrogen jet fire from a pipe was detected by a night operator making rounds in a solvent production unit. The unit's emergency response team managed the fire in minutes. Operators stopped the flow…
[NOTE of HIAD Validator: the attribution to hydrogen formation as cause of the explosion is 'probable 'but not fully demonstrated]. Two explosions in two different sprinkler systems occurred, wit the…
The event occurred in a bus garage when carrying out the purging process of the hydrogen cylinders. This process was executed via an electronic control system, but it was found that one cylinder…

The release occurred during refuelling of the mobile storage system. This operation was part of a series of tests aiming at verifying the tightness of the system. When opening a valve to connect…

The fire took place during maintenance works in one out of the three gas extractors of the coke process line. Main cause was displacement of a flange which allowed the entrance of flammable mixture…

A large hydrogen gas leak from a dewar resulted when bolts holding fitting the top of the tank was loosened. The fitting contained instruments. On loosening the third bolt, hydrogen gas excaped…

During a welding operation on a LH2 fill line it was discovered that LH2 was still in the tank although it should have been drained. Hence the potential for a major explosion existed. [Ordin, NASA…