Skip to main content

HIAD Facility - Location Type: Open


A large hydrogen vapor cloud was released from the base of a bulk hydrogen storage tank, at special gas company. The cloud found an ignition source producing a large fireball, shook windows in the…

The day before the incident, the outlet pipe connected to methanation reactor started leaking gas, which contains hydrogen. The leak was temporarily eliminated by a pressurised plug. On the day of…
A gas mixture (25% nitrogen, 73% of hydrogen, 2% methane) leaked, due to the ejection of the check valve from its connection with the inlet pipe. A large amount of the gas mixed with air and ignited,…
An explosion occurred at testing facility of a space rocket engine. The incident occurred when executing a test studying the performance of a hydrogen gas flow measuring system for fuel feeding…

A large quantity of hydrogen was being vented to atmosphere during pre-chill operations. Normal pre-cooling time was about 45 minutes, but due to technical problems, the pre-cooling continued for…

This incident occurred at the electrolyser of a refuelling station. An employee of the electrolysers manufacturer was on-site to conduct a reset of the plant power breaker system and to restart gas…
This incident occurred unit at a demonstration of a new technology for the catalytic cracking of vacuum residual oil. An oil storage tank failed due to high pressure. The overpressure in the tank was…
The incident occurred at an indirect oil desulphurisation unit, and originated on a piping at the outlet of a heat exchanger. The exchanger was located in the furthermost downstream of the reactor.…
A fire and explosion occurred at a catalytic reformer unit. The fire centred between the reactors and fired heaters of the reformer and resulted in extensive damage to the unit. The explosion rocked…
The accident occurred in the hydro-cracking unit, specifically in its sulphur recuperating system. The location was on a 8" piping, which cracked at a a 90° bend. Due to the loss of confinment, a…
Explosion at hydrogen unit operated workers evacuated, 2 injured, community rattled.
The explosion occurred inside the lower hydrogenation tower of a hydrogen peroxide unit, damaging the distribution tray inside the tower. it caused 4 fatalities, 2 injuries and considerabledamage to…

A hydrogen explosion occurred at the hydrogen storage unit of a power generation plant. A burst disc opened, releasing approximately 3 tons of hydrogen. The leaked hydrogen formed an explosive…

An hydrogen explosion occurred at a reailway station during shunting. Two rail cars collided, one ruptured. Nothing further is known. The following explosion was classified as BLEVE (boiling liquid…
An explosion occurred on a tank truck whilst unloading hydrogen into a storage tank. The explosion occurred near the discharge valve of the truck injuring two people and starting a fire at the point…
A series of explosions occurred on an industrial estate on a trailer containing 80,000 cubic feet of hydrogen. Hydrogen was being transferred from the trailer when it leaked, ignited and exploded.…
Two explosions rocked the industrial area of Santa Clara afternoon June 1st 2019, sparking a smoky fire at a chemical, gas storage and transportation facility of Air Products and Chemicals Inc. near…

A hydrogen explosion took place at renewable energy power plant. The site was still under construction and consisted in two hydrogen 9MW fuel-cell systems. The explosion is reported to have taken…

A explosion occurred in the gas and dust treatment system for the aluminium holding furnaces at a metallurgical plant. The explosion caused the failure of the treatment system, the operation of…

An explosion occurred at the fume treatment unit of a foundry. The fumes contained chlorine, used in the metal treatment process. The treatment unit function by spraying water and caustic soda.…