The event occurred during the decommissioning of a nuclear power plant. It involved a tank containing 100 kg of residual sodium from the decommissioned experimental nuclear reactor which was using…

A release of hydrogen and steam occurred in the battery room of a nuclear power plant around 21 h. Site agents neutralised the batteries. Noting the failure of the smoke extractor, public…

A contained explosion in a hydrogen tank occurred at the thermal generation plant
The event occurred in the steam condensing line of the residual heat removal system the nuclear reactor. Radiolysis generated hydrogen and oxygen, which then accumulated in high concentration in the…
An explosion occurred inside a pipe of a boiling water nuclear power reactor. The pipe was part of a core spray system, which was providing extra cooling when shutting down the reactor. The system…

The DC power system was serving as back-up power and was based on a battery storage system. It had been taken off-line to be replaced with a more modern system. After its replacement, at the…

A hydrogen explosion caused burns contaminated with radioactive dust to a member of the plant's maintenance crew. Three other workers escaped injury. The accident occurred in the basement of the…
An hydrogen explosion occurred within the off-gas system, causing the stop of the sump pump; subsequently both trains of the standby gas treatment system were declared inoperable. The sump is part of…

A hydrogen explosion occurred at the hydrogen storage unit of a power generation plant. A burst disc opened, releasing approximately 3 tons of hydrogen. The leaked hydrogen formed an explosive…

A hydrogen explosion occurred at a 585-MW coal-fired supercritical unit and caused one fatality, injuries to 10 other people, and significant damage to several buildings. The explosion occurred…
A tank leaking hydrogen at an electrical power plant exploded.

A hydrogen explosion took place at renewable energy power plant. The site was still under construction and consisted in two hydrogen 9MW fuel-cell systems. The explosion is reported to have taken…

This entry reports only the role of hydrogen in this nuclear accident. For a short description of the initial causes and the incident evolution, see "pre-event summary” and for a much more detailed…
A steam turbine/generator tripped due to an unknown hydraulic control oil system failure. The generator breaker opened, but the emergency valve (throttle valve) did not closed completely. Within 30…

Explosion as a result of detonation of gases inside container in turbine section causing 2 casualties .

Explosion in generator area, thought to be hydrogen leak as a result of radial lead seal failure. Extensive plant damage.
An in-tank explosion occurred in a gaseous waste decay tank while the plant was in cold shutdown. The gaseous hydrogen present in the tank formed a flammable mixture and ignited due to air…
This incident occurred at the hydrogen production and storage unit of (probably) a power plant using hydrogen as a coolant of the turbine-generator system. Hydrogen was produced probably by water…
The accident occurred in a disposal storage for contaminated waste, consisting in a 65-metre shaft flooded with seawater. At the origin of the explosion was the reaction with water of at least two…
In an electricity production plant, hydrogen leaked from a tank supplying the colant to the generator. The leaked hydrogen iognited and formed a fireball. Possible involvement of sealing oil not…