Skip to main content

Explosion of radioactive waste due to metals-water reactions (672)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Explosion of radioactive waste due to metals-water reactions

The accident occurred in a disposal storage for contaminated waste, consisting in a 65-metre shaft flooded with seawater. At the origin of the explosion was the reaction with water of at least two kilograms of sodium and potassium. They reacted violently with the water, producing hydrogen. The explosion opened the ceiling of the storage. A plume of white smoke blowing out to sea was reported by witness. Probably also an emission of radioactive particles occurred.
Event Date
March 1, 1977
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
According to some report, the accident was possible due to lack of waste disposal control (inadequate safety design, inventory, monitoring).
Facility Information
Application Type
Application
Nuclear power plant
Specific Application Supply Chain Stage
Components Involved
radioactive waste storage (odium and potassium)
Location Type
Location description
DESCRIPTION of the FACILITY The power plant was an experimental fast-breeder reactor of 15MW, liquid sodium-cooled, which started operations in 1959. The waste shaft was containing intermediate level waste.
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Post-event Summary

According to one of the sources, the explosion blew off the shaft’s concrete lid, threw its steel top plate 12 metres to one side, badly damaged the 5-tonne concrete blocks at the mouth of the shaft, and blasted scaffold poles up to 40 metres away. A plume of white smoke blowing out to sea was reported by witness. Probably also an emission of radioactive particles occurred.

Lessons Learned
The role of hydrogen in this event is only secondary. It was produced by the reaction of sodium and potassium containing waste with water: 2Na + 2H2O → 2NaOH + H2. The reaction is explosive, and the ignition of hydrogen can contribute to the overall energy release. Because of this hazard, in this fast-breeder reactor hydrogen sensors were installed at the sodium side of the heat exchanger between the primary coolant circuit (sodium) and the secondary circuit (steam, water). The possibility of a reaction was not considered in the waste storage.
Event Nature
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

NewScientist article of 24 June 1995 https://www. newscientist. com/article/mg14619830-600-lid-blown-off-dounreays-lethal-secret/ (accessed November 2020)

For a description of the reactor, see: S. E. Jensen, P. L. Olgaard Description of the Prototype Fast Reactor at Dounreay, 1995, NKS/RAK-2(95)TR-C1, Risoe National Laboratory DK-4000 Roskilde, Denmark

For a general overview of fast breeder reactor problems: M. Lehtonen, J. Lieu The rise and fall of the fast breeder reactor technology in the UK: between engineering “dreams” and economic “realities”? 2011, University of Sussex