This accident occurred at the unit producing synthetic adhesives by adding hydrogen to petroleum resin under high temperature and pressure. Hydrogen was added to the reaction via a supply pipe at the…

The incident occurred at a hydrogen compression facility, due to a leaking fitting a the pressure relief fitting. The hydrogen was released through the pressure relief inertised line. It ignited…

A mixture of mainly carbon monoxide and hydrogen was released from a pipeline transferring process gases in a not further specified unit of a chemical plant, generating a flammable mixture which…
An explosion occurred in the transformation section of a fertiliser manufacturer, resulting in 8 deaths and 3 injuries. A leak in the secondary pipeline of the 1st conversion system, and caused the…

The event occurred during a pressure testing of a LH2 pump discharge system. A weld joint failed at an internally tied bellows. The weld failed at 1100 psi (ca. 76 bar) while the test pressure…

A lightning strike ignited the hydrogen exiting a stack in a chemical factory. The hydrogen, produced by the chlorine electrolysis cells, was conveyed to the stack when the manufacturing unit using…
A 9000 gal (34 m3) LH2 storage tank exploded during repair of the vent stack. Few days before the explosion, the tank had been filled with LH2, but later on the hydrogen released and ignited at the…

A rupture disc opened on a 76 m3 (20,000-gallon) liquid hydrogen tank, causing the vent stack to release cold gaseous hydrogen. The gas ignited causing a fire on the vent stack's outlet.…

According to local news, a "hydrogen tanker truck hauling was on fire" at a travel centre on a highway. The videos show, however, simply a flame from what probably is the pressure relief…

A hydrogen leak occurred at a plant's hydrogen fill station. After having transferred the load to the plant station storage system, a tube trailer pulled away and caught a hydrogen fill line.…

Motorway accident which involved a large quantity of vehicles and a gaseous tube trailer which transported gas hydrogen in pressure. Some cars were burning under the back part of the gaseous tube…
In 1987, well diggers had drilled a well for water, but had given up on one dry borehole at a depth of 108 meters. According to the source reported in the References, “…wind was coming out of the…

The second stage of the Saturn V (S-II-T) was under full-duration static test, when one fire near LH2 valves of the LH2 tank and another in the engine area caused the automatic termination of the…

In a paper plant, an explosion occurs in a paper pulp tank while 2 workers were carrying out pipes cutting with a grinder on the roof of the tank. Detailed analysis of the event was performed by two…

A fire broke out at a pipe of the hydrogen production unit, belonging to the steam methane reformer part of the fluidised catalytic cracking (FCC) plant. The fire occurred when personnel of a…

A series of explosions at an oil refinery reformer unit caused by a rupture to an 8 inch naphtha and hydrogen feed pipe. Fire officials cited higher than normal line pressures just before the blast.…
A hydrogen explosion ruptured and fragmented a 6-inch steam condensate pipe elbow at of a nuclear plant. The component affected was a steam piping of a heat exchanger used for removing residual heat…
The fire broke out on a worm ("vis sans fin") supplying a conveyor of aluminium. The ignition of the powder on the ground was caused by the flame cutting operation on the worm shell which generated…
The utility production facilities (electricity, water, air, and steam) at a refinery were isolated from the power grid and switched to two turbine generators in anticipation of a storm. However, at 9…

While a H2 sample was being prepared for an analysis, one of two cryogenic sample bottle disks ruptured and the gas ignited. [Ordin, NASA (1974)]