Skip to main content

HIAD Classification of the Physical Effects: Hydrogen Release And Ignition


During a routine inspection, a flame was observed at the bottom flange of a reactor in a refinery. Few moments later, sensors near the leak detected a rise in temperature. The facility was shut down…
During a work tour on a refinery, an employee noticed a fire at the level of a flange at the inlet of the grille of an exchanger, located at the outlet of a reactor of the catalytic reforming unit.…
A diesel and gas leak (H2, H2S, CH4) occurred in a hydrodesulphurization unit (2,200 t/d). The leak location was on one of the boiler valves of the stabilization column. The released mixture (390 °C…
The leak ignited at the seal located between the bottom and the body of a heat exchanger of a desulphurization unit of a refinery. The fire is alimented by the leaking fuel under pressure for about…
Hydrogen ignition during welding on a VSC-24 spent fuel cask Pursuant to 10 CFR 72. 210 - fuel in an independent spent fuel storage installation at its Point Beach Nuclear Power Plant. The inspection…

A hydrogen explosion occurred in a 5-tonne stainless steel pressure vessel, while two electro-polisher workers where electropolishing internal surfaces. The cause is believed to be the build-up…

A fire, fuelled by a mixture of gasoline and hydrogen, occurred on a heat exchanger located at 15 m height in a gasoline processing unit of a refinery. The operator triggered the emergency plan. Site…

The incident occurred at a reactor vessel of a naphtha hydrotreater unit. The vessel operated at around 25 bar and 140 C. A 1. 5-meter crack opened up in the reactor vessel close to welded vessel…

A Worner 1000 STU gas balloon, of German registry D-OAGH, piloted by a commercial pilot was substantially damaged during landing, when the hydrogen-filled envelope came in contact with a power line,…
An explosion occurred while inflating a balloon with hydrogen gas. The News reported the involvement of the hydrogen bottle.
An accident occurred before the start of a scientific demonstration at a school. Part of the school demonstration was about hydrogen-oxygen balloons. To prepare for the demonstration, the…
This incident invovled a tank which was inside a car parked in a hospital underground parking garage. The tank was supposed to be used for launching a weather balloon. The hydrogen possibly leaked…
A hydrogen car caught fire at a hydrogen fuelling station. During refuelling of a H2-fueled car the owner heard an abnormal noise and opened the fuel filler door to investigate. A small fire then…
An explosion and fire occurred at a reciprocating recycle hydrogen compressor during commissioning of a new Diesel hydrotreatement Unit. It happened during the reactor pre-sulphidisation step, when…

hydrogen gas cylinder explosion and subsequent fire in an electrical products company. 3 fatalities and 8 injuries. [Note of the validator: while the majority of the news report as cause the…

[NOTE of HIAD Validator: the sources are not completely clear in describing the system involved in this incident ; the following is the most plausible option ] The explosion happened in two hydrogen…
Hydrogen explosion at a chlorine chemical production plant (Seveso-classified)The plant had been shut down for two weeks, and maintenance works were ongoing. Two subcontractor employees were cutting…
The accident occurred at a distillate dewaxing Unit (MDDW) of the refinery, during the operation of regeneration of the catalyst. To perform this operation, both temperature and pressure have to be…

This incident occurred at a hydrogen refuelling station with on-site hydrogen production based on reforming of city gas and natural gas. The part affected was a coil in the heat exchanger…

A hydrogen gas explosion occurred at the hydro-treating unit of a renewable diesel plant. The explosion was followed by a fire which was extinguished an hour later by the local resources. Two…