A deflagration occurred during shutdown of a reactor used for ammonia synthesis. It was followed by a jet fire. The hydrogen leak was probably due first to the lower seals, followed by another leak…
Hydrogen explosion on NPO "Azot" in Rovno, Ukraine.

A series of explosions occurred in a converter where hydrogen is extracted from ammonia. A fire occurred as a result of the incident.

A runaway chemical reaction happened in a reactor containing methanol and a substance to be hydrogenated. A large quantity of hydrogen was released; a balloon containing a borohydride exploded.…

The explosion occurred while restarting the ammonia reactor. Synthetic gas (70% H2) was released at the flange of the relief valve of the turbo-compressor. The explosion was followed by a jet fire.…
The explosion occurred in the compressors unit of the plant. Witnesses reported a cloud of yellow smoke and a fire ball at its bottom. This first event was followed by a fire fed by a hydrogen pipe…
A syngas leak (hydrogen + methane) occurred at exit of the ammonia production reactor and led to an explosion followed by a fire. The start point of the sequence of events was the syngas at the…

[Note of the event validator: according to the sources, hydrogen as combustible gas does not seems to have plaid part in this incident. However, it is more plausible that hydrogen, as the main…

An explosion involving hydrogen occurred at cooking oils and other food products plant. It was located at the hydrogen storage tank and caused one injury and two fatalities. The area directly…

A release of "synthesis gas", containing primarily hydrogen occurred at the ammonia synthesis unt of a fertilisers plant. The location of the leak was a valve within the ammonia synthesis column. The…
An explosion and fire occurred at night inside a unit for the synthesis of toluene di-amine. The process implied the hydrogenation of di-nitrotoluene in presence of isopropanol as solvent and Raney…
An explosion occurred caused by a leak of hydrogen from a reactor on a fertilizer plant. The blast hurled the head of a hydrogen gas converter 150m and sent it crashing through reinforced-concrete…
The incident occurred at the chlorine electrolyser. Failure of a strainer allowed sand from brine filters to get into mercury cells in a chlorine plant. It appears that the sand obstructed the flow…
The vent occurred in the ammonia production unit. A minor leak had been detected in a flange on the piping of the ammonia synthesis loop (operating at 250 bar). The company called a specialized…
A gas release occurred in the building containing the compressors for the recirculation of process gas of a plant producing fertilisers. The process gas was a mixture of hydrogen and nitrogen. It…
The explosion occurred in the ammonia/hydrogen separator of the ammonia reactor due to metallurgical problem.
A release of a mixture of hydrogen, nitrogen and ammonia ignited and exploded in the ammonia synthesis unit. The release was due to a cracked pipe and occurred at the level a flange situated at the…
The event took place in the on one out of the seven reactors for ammonia synthesis. The day of the accident, preparation works for the decennial pneumatic test (previous pneumatic test was carried…
A mechanical failure occurred in a gasification reactor, which caused a violent (abrupt, sudden) depressurisation of the reactor. The consequences were the projection of tiles of the refractory…
The event occurred at the hydrogen production unit of the ammonia production plant. An air-hydrogen mixture formed in the building hosting a water pump which fed water to a vessel that contained…