A fire occurred at a hydrogen refuelling station for buses. The incident was initially reported as an explosion due to a loud noise and vibrations felt in nearby buildings. However, subsequent…

This incident occurred in a unit processing vegetable oils and fats. the explosion occurred in a hydrogenation facility, specifically where hydrogen is processed with a very high-pressure (400 bar).…
The event occurred on a hydrogen pipe of a sodium chlorate plant. The on-duty field technician noticed a self-sustained ignition on the pipe. The flare-like flame of less than one metre in height was…
The fire occurred in a unit to produce hexamethylenediamine, an organic compound precursor of polymers (HMD). The process is based on the hydrogenation of a precursor in presence of a catalyst. A jet…
First an explosion and then a fire occurred on the condensate piping of an chlorine electrolysis plant (SEVESO upper tiers). Flames escape from the end of the pipe and spill into a 75 m³ open sky…
Fires and chain reactions involved more than 100 cylinders of hydrogen or other gases in a storage system. The fire lasted for more than 5 hours and the neighbourhood has been affected by flying…
A jet flame occurred in a diesel distillation unit. It was caused by the release and ignition of hydrogen from the low-pressure (60 bar) section of a the unit. It occurred during maintenance works…
A jet fire occurred on the ammonia production unit, caused by a leak on a hydrogen pipe. Hearing a strange noise, an employee triggered the alarm after having discovered an ignited jet of hydrogen.…
Leak from faulty hydrogen seal ignited by short circuit between inboard slip ring and outboard slip ring radial lead connection. Hydrogen flame caused damage to brush gear assembly and inboard slip…
An isolation failure in starter coil of the high voltage generator induced an electric arc to the hydrogen supply line, with consequent fire and melting of the line. [Zalosh and Short, 1978]
The fire was the consequence of the malfunctioning of a hydrogen compressor. This compressor was used to supply hydrogen to a reactor unit amining at increasing gasoline octane values.
A leak occurred on a 4 inch hydrogen main gas line which ran along a pipe bridge at the east end of a first stage compression plant building. The relased hydrogen ignited. The source of ignition was…

The fire developed in a hydrogen production plant serving an food manufacturer. A high-pressure compressor line (non-further specified) ruptured. It was impossible to use isolation valves to limit…

A hydrogen leak in the hydrogen compressor unit of a filling station ignited causing the shut down of the whole station. The loss of containment was due the failure of a tie rod (diameter ~64mm) ,…

Employees were refilling a rack of 15 hydrogen cylinders that were connected together on a steel pallet with railings. A leak developed at a valve and the pressurized hydrogen ignited. Operations…
A fire in a leaking hydrogen unit at a 220,000-barrel oil sands plant temporarily cut production nearly 80 percent.
The hydrogen release of a defect valve on the hydrogen supply line ignited due to an unknown cause. The fire caused the melting of soldered joint with consequence additional release of hydrogen at 6.…
Fire on a filter of an autoclave. The event occurred in a plant for the production of plastics. After catalytic synthesis of amines, the filter of the autoclave was taken out for cleaning. During the…
A deflagration occurred at a chemical plant during a synthesis operation involving sodium tri-acetoxy-borohydride inside a 5,300-litre reactor. Around 5:30 pm, the technician observed that the acetic…
The event occurred in fire in a classified-Seveso metallurgical plant. A fire initiated in a acid treatment reactor of a workshop handling cementation of indium . Under normal conditions, the…