A liquid hydrogen tanker was en route on the highway when the driver noticed a vapour plume in the rear-view mirror. The driver exited the highway and stopped at the first available safe location.…
A liquid hydrogen tanker was traveling west bound on a highway, when adverse weather conditions (snow and wind) caused a brief "whiteout". To avoid a group of vehicles stopped in front…
This near miss affected a testing installation for liquid hydrogen. A leak was located on a valve installed on a purge line connected with a LH2 storage tank. This shut-off valve served to…
Excessive delay in trip resulted in over-pressure on the liquid hydrogen tank, requiring manual venting. This resulted in releasing of 2750 cu ft of hydrogen [Zalosh and Short, 1978]
The drivers failed to lower the internal pressure of a liquid hydrogen tanker before leaving plant. Therefore they had to stop en route and vent 4000 scf of hydrogen. [Zalosh and Short, 1978]
A liquid hydrogen tanker was returning empty to the base, when a pressure build-up forced the drivers to perform a manual venting. [Zalosh and Short, 1978]
The drivers failed to stabilise the tank pressure after having delivered the liquid hydrogen. Therefore they had to stop and perform a manual vent on journey back to the base. [Zalosh and Short,…
Before loading it with liquid hydrogen, the cyrogenic tank had been purged with nitrogen for maintenance work. After the loading, the drivers failed to stabilise the internal pressure of the tank,…
A pressure build-up in the tank of a liquid hyrogen tanker caused the drivers to vent 6000 cu ft of hydrogen to reduce the pressure. [Zalosh and Short, 1978]
Pressure buildup in tank was manually vented by driver releasing 1000 cu ft [Zalosh and Short, 1978]
The tank of a liquid hydrogen tanker was manually vented prematurely on its empty return trip. 9,000 cu ft werereleased [Zalosh and Short, 1978]
While returning to the base, a liquid hydrogen tanker had to be vented twice. The cause of the overpressure was a malfunctioning scale which allowed a slight overload of hydrogen. [Zalosh and…
This near-miss occurred at a company producing compressed gas bottles according to customers requests. When preparing a gas mixture containing oxygen and nitrogen, by mistake hydrogen was added,…
At an off-site LH2 fill station, a LH2 trailer hit the GH2 purge shut-off valve handle. The tubing attached to the purge valve was bent on both ends but did not leak. [Ordin, NASA (1974)]