Skip to main content

Hydrogen release from a LH2 tanker (113)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Hydrogen release from a LH2 tanker

A liquid hydrogen tanker was en route on the highway when the driver noticed a vapour plume in the rear-view mirror. The driver exited the highway and stopped at the first available safe location. Upon inspection of the cargo, the driver noticed that the pressure in the inner vessel of the double-walled tank had risen above 3. 45 barg (50 psig), causing the opening of the safety relief valve. Later, a thorough inspection revealed a leak in the annular space vacuum relief plate, leading to a loss of vacuum. That failure increased the heat transfer to the cryogenic hydrogen, consequently increasing vaporisation.

Event Date
June 27, 1996
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The INITIATING CAUSE was a loss of vacuum of he insulation shell of the liquid hydrogen tank. The Pressure Relief Device (PRD) worked as expected.

Facility Information
Application
LH2 tanker
Specific Application Supply Chain Stage
Components Involved

PRD

Storage/Process Medium
Storage/Process Quantity
3500
Actual Pressure
0
Design Pressure
0
Location Type
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Property Loss (onsite)

0

Property Loss (offsite)

0

Post-event Summary

This is a near miss. The PRD functioned as expected, releasing the hydrogen vapour in overpressure

Lessons Learned

This is an example of a successful mitigation of a mechanical failure. On a liquid hydrogen tank, the function of the Pressure Relief Device (PRD) is to release hydrogen vapour, when the tank internal pressure increase due to the evaporation of liquid hydrogen. The reduction of the insulation capacity of the tank accelerated the evaporation rate and the PRD released more vapour. In this way, the internal pressure of the tank remained below the maximal allowed value.

Event Nature
Emergency Action

No emergency action was necessary: the pressure in the inner vessel of the double-walled tank had risen above 3. 45 barg (50 psig), and the safety relief valve opened to release excess hydrogen vapour.

Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Event incident ID I-1996071466 of the PHMSA database (Pipeline and Hazardous Materials Safety Administration, 1996), https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages (accessed September 2024)

A. Jimenez, C. Groth, Hazards associated with pressure relief devices in hydrogen systems, Journal of Loss Prevention in the Process Industries 91 (2024), 105380, https://doi. org/10. 1016/j. jlp. 2024. 105380