Hydrogen release from a LH2 tanker
A liquid hydrogen tanker was en route on the highway when the driver noticed a vapour plume in the rear-view mirror. The driver exited the highway and stopped at the first available safe location. Upon inspection of the cargo, the driver noticed that the pressure in the inner vessel of the double-walled tank had risen above 3. 45 barg (50 psig), causing the opening of the safety relief valve. Later, a thorough inspection revealed a leak in the annular space vacuum relief plate, leading to a loss of vacuum. That failure increased the heat transfer to the cryogenic hydrogen, consequently increasing vaporisation.
Event Date
June 27, 1996
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes

The INITIATING CAUSE was a loss of vacuum of he insulation shell of the liquid hydrogen tank. The Pressure Relief Device (PRD) worked as expected.