HIAD Nature of the Consequences: Fire


As the airship approached the docking mast, it performed a sharp turn to face into the wind, which was shifting. The engines were run at full speed astern for about a minute to slow the airship. Dust…
A trailer-tractor transporting hydrogen cylinders veered off the road to the right at around for unclear reasons and eventually tipped over to the left. Part of the 4,000 cubic meters of hydrogen…

Near the end of the process of filling a gaseous hydrogen tube trailer at a liquid hydrogen trans-filling station, a safety pressure-relief device (PRD) rupture disc on one of the tube trailer’s…

While driving on a highway, the driver of a CGH2 tube trailer was notified by another driver of the smoke coming from his trailer. The CGH2 tube trailer parked in a place considered safe,…

A release of compressed hydrogen and subsequent fire occurred during the transportation of a CGH2 trailer by means of a truck tractor. The tube trailer module contained 25 fully wrapped carbon filler…

Safety slug in the vent pipe of a hydrogen trailer failed, damaging the pipe and causing a hydrogen leak. The following fire damaged several other trailers. [Zalosh and Short, 1978]

In a hydro-desulphurisation unit of a refinery, an operator which was performing a control tour heard noises and clicks on the hydrogen compressor and stopped it. The compressor was of a…

30 pounds of gaseous hydrogen (14 kg) were accidentally released from a heat exchanger at a refinery. The location was the flange between the heat exchanger channel and shell and occurred during…

A hydrogen fire occurred at a hydrogen refuelling station (HRS). The HRS hydrogen storage consisted of two trailers at 200 bar, both connected via flexible hoses to the station delivery system…

Failure of an 8 inch steel outlet pipe from a gas heater which ruptured and allowed hydrogen to escape with ensuing rapid ignition.

Gaseous hydrogen release in generator caused by turbine vibrations [Zalosh and Short, 1978]

The event occurred at a high-temperature heat of at a benzene manufacturing plant using a dealkylation reaction. High-pressure hydrogen leaked from a flange of the heat exchanger, during start-up…

In a petrochemical plant, visual inspection detects fumes under the heat insulation of a heat exchanger operating under hydrogen pressure. The first intervention team was mobilized and the unit…

The incident occurred in the hydrogen sulphide absorption tower of the kerosene desulphurisation unit of a refinery. The hydrogen leaked from the liquid level gauge and ignited causing a fire. The…

The fire developed an early morning on a hydrogen bus at a refuelling station for public transport. According to the bus company release, one bus was destroyed by fire suring refilling and the…

A fire started in the night on one of the fuel cells and hydrogen bus of a garage of a public transport company. There were seven buses parked on a parking lot outside. 6 buses were destroyed by…

The event occurred during the disconnection of the hydrogen compressor for maintenance. Two deaths and three injured workers were the consequences. The cause(s) of the event are unknown .
The incident occurred at a refinery unit for the desulphurisation of a light heavy oil. This unit was equipped with three hydrogen compressors. Two of them were usually operated and the third was…
A hydrogen leakage caught fire in the hydrogen compressor area of the continuous reforming unit. The reforming unit and the hydrocracking unit were immediately stopped. The hydrogen flow was cut off,…
A flash fire enveloped a hydrogen compressor at a refinery.