Skip to main content

HIAD Nature of the Consequences: Fire


A fire was caused by a hydrogen leak and led to the formation of a fireball at the end of a hose at the conditioning station. It occurred while transferring hydrogen from a stationary storage to he…
The fire occurred around 13:20 on three cells of the chlorine manufacturing unit. A leak of hydrogen in the electrolysis room was at the origin of the fire; the ignition of the H2 cloud caused a…
The fire occurred on a flange of a hydrogen supply line to a desulfurization reactor unit of diesel, which leaked and ignited (30 cm flame) The leak was stopped by isolating the part of line affected…

A hydrogen fire broke out at the aft end of the orbiter connected to the LH2 onboard tank of a space shuttle. This happened during the abortion of the launch, occurred due to another cause, the…

On February 3, 1994, a control room operator at Surry Power Station, Unit 1, observed pressure spikes on the pressurizer level instruments. At the same time, a loud rumbling sound was heard in the…

A truck transporting hydrogen and oxygen cylinders collided with a passenger vehicle at an intersection and overturned, causing all cylinders containers to fall onto the road. Gas leaked from four…

Following the first flight of the Montgolfier brothers, the first severe accident with hydrogen on a Montgolfier-balloon occurred in 1785, when trying to cross the Channel from France to England. Two…
A fire broke out on the world’s first hydrogen carrier vessel shortly before setting sail from Australia to Japan carrying the world’s first international shipment of liquefied hydrogen. A flame was…
Hydrogen leaked and ignited on a cell in the sodium chlorate (NaClO3) workshop of a chlorinated products plant. There were no victims and no damage to the environment. On-site firefighters controlled…
The event occurred in a university research building dedicated to the study of the take-off of space launchers . An operator gave the alarm during the hydrogen pressure pre-setting phase. he had seen…
The fire took place during maintenance works in one out of the three gas extractors of the coke process line. Main cause was displacement of a flange which allowed the entrance of flammable mixture…
This accident occurred at the unit producing synthetic adhesives by adding hydrogen to petroleum resin under high temperature and pressure. Hydrogen was added to the reaction via a supply pipe at the…

The incident occurred at a hydrogen compression facility, due to a leaking fitting a the pressure relief fitting. The hydrogen was released through the pressure relief inertised line. It ignited…

A lightning strike ignited the hydrogen exiting a stack in a chemical factory. The hydrogen, produced by the chlorine electrolysis cells, was conveyed to the stack when the manufacturing unit using…

According to local news, a "hydrogen tanker truck hauling was on fire" at a travel centre on a highway. The videos show, however, simply a flame from what probably is the pressure relief…

A hydrogen leak occurred at a plant's hydrogen fill station. After having transferred the load to the plant station storage system, a tube trailer pulled away and caught a hydrogen fill line.…

Motorway accident which involved a large quantity of vehicles and a gaseous tube trailer which transported gas hydrogen in pressure. Some cars were burning under the back part of the gaseous tube…

[NOTE of the EVENT VALIDATOR: this is a natural gas event, related to the NG supply chain. It may be however of interest for hydrogen-NG mixture transportation in pipeline. ] A 30-inch natural gas…

In 1987, well diggers had drilled a well for water, but had given up on one dry borehole at a depth of 108 meters. According to the source reported in the References, “…wind was coming out of the…

The second stage of the Saturn V (S-II-T) was under full-duration static test, when one fire near LH2 valves of the LH2 tank and another in the engine area caused the automatic termination of the…