The event occurred on vent stack of an ammonia synthesis unit. The release of the gas was more specifically on the water purge line or the hydraulic guard of the vent stack. The process gas…
An incident occurred on a compressor at a refinery Fluid Catalytic Cracker Unit (FCCU) plant involving hydrogen. Source of ignition was hot surface.
A release of hydrogen occurred during the filling of a 28 bottles rack. A worker decided to move the rack from one station to another, due to works ongoing nearby. This movement, even though the hose…
[NOTE of HIAD Validator: One source speak of a hydrogen gasometer, Spanish news speak in general of gas, others of natural gas or coal gas; considering the main product of the factory, it was chosen…
A weld on a 1 inch diameter instrument tapping from a Octafiner reactor overhead line fractured, resulting in a small but intense fire, lasting about 50 minutes until the unit was nitrogen purged.…
A fire developed on a mathanation reactor. The methanation reactor vessel was found to be deformed and had a 3-4 inch rupture at a position corresponding to the top of the catalyst bed. It is thougth…

At a chemical processing plant, a release of pressurised hydrogen gas resulted in an explosion and fire injuring lightly three workers and causing damage to plant. The incident occurred during the…

In a chemical plant, a fire broke out on a hydrogen column of an ammonia manufacturing unit. The internal security service extinguishes the fire with powder and nitrogen injection. The unit was…
A hydrogen leak occurred on a 50 mm pipe feeding a reactor. The leak ignited spontaneously when mixed with air. Thanks to the closing of the input and output valves, the quantity released could be…

This incident occurred a product purge vessel flange during planned maintenance activities on a chemical plant. The vessel had the function to collect unreacted gases from a polyethylene…

In a plastics production plant, a pallet containing 7 cylinders of nitrogen and 1 cylinder of hydrogen fell from a truck traveling in a logistics zone. The driver stopped the vehicle, cut off the…
In a petrochemical plant, a gas mixture at 270 bar made of 75% hydrogen (H2) and 25% methane (CH4) leaked through the bottom valve of a dryer of a resin production unit. After detection of the leak,…
Hydrogen explosion at a chlorine chemical production plant (Seveso-classified)The plant had been shut down for two weeks, and maintenance works were ongoing. Two subcontractor employees were cutting…
The event occurred at manhole cover of a of a pilot plant reactor where hydrogenation had been performed in a hydrochloric aqueous solution. The reactor had been flushed three times with nitrogen (i.…
The explosion occurred when an operator opened a valve on the hydrogen network of the plant. The operator suffered from a burn in the forearm and two other employees were shocked by the pressure wave…
The incident occurred in a building containing the residues of the production of sodium, lithium and chlorine. The alarm was given by an employee who heard detonations coming from the building. A few…
In a chemical plant (SEVESO), corrosion on the water side of a cooling exchanger caused water to enter the sulphuric acid and attack the steel in the tank. This reaction produced hydrogen that…
The sodium chlorate production unit had restarted after a maintenance shutdown phase. The mercury cells had been under nitrogen flushing since the beginning of the shutdown to avoid the presence of…
The event early on a Saturday morning, when the plant was thus practically empty. Nevertheless, the chronology of the accident can be reconstructed from the testimonies of the few operators who were…
The fire broke out in the acid etching tank of the ferric chloride manufacturing unit of a SEVESO-classified chemical plant. In this tank, the attack reaction of the iron metal with hydrochloric acid…