The incident occurred at the hydrocracker unit, which was being shut down for maintenance and the reactor was in a hydrogen purge cycle. A hydrogen gas line failed at a weld. The line was at 3000 psi…
Three workers were working in the sulphur recovery unit (SRU), trying to restore the hydrogen flow. The workers were trying to isolate the cause of a flow problem: hydrogen was entering the…
On February 3, 1994, a control room operator at Surry Power Station, Unit 1, observed pressure spikes on the pressurizer level instruments. At the same time, a loud rumbling sound was heard in the…
The event occurred at a pit furnace for metal component treatments. The hydrogen feed system for the furnace developed a leak, located on the hydrogen dryer inside a shack attached to a building. The…
The station was storing 6,000 litres of liquid hydrogen in ten tanks. Rescue services were alerted and the station's activity is interrupted. The leak was stopped by closing the valves. According to…
Hydrogen release from a road truck transporting liquid hydrogen
the commercial vehicle was traveling when the two-person crew noticed what appeared to be smoke emitting from the tanker trailer. The crew called 911 and safely pulled to the side of the roadFire…
A leak occurred on a relief valve of a high pressure hydrogen storage tank. No explosion or fire occurred.
At a linear accelerator site, a hydrogen retort exploded during ignition of burn-off gas. One employee experienced hearing loss in one ear and a shoulder injury from being blown into a cabinet. A…
A tanker carrying liquid hydrogen overturned without rupturing. Traffic on an interstate highway was closed throughout the afternoon and evening.
A potentially explosive situation was reported by safety inspectors at a nuclear waste tank. The waste slurry had formed a thick crust which was trapping hydrogen being continuously generated…
A liquid hydrogen tanker was travelling back to the base after having made an earlier delivery. At the end of the delivery, the pressure in the tanker had been reduced to 75 psig using the vent stack…
A full liquid hydrogen tanker was approaching a stop at a vehicle weight station, when the driver noticed vapours coming from the tank vent. The driver parked the vehicle, inspected the tanker and…
A hydrogen pipe burst at a semiconductor plant injuring 1 person
A series of explosions at an oil refinery reformer unit caused by a rupture to an 8 inch naphtha and hydrogen feed pipe. Fire officials cited higher than normal line pressures just before the blast.…
A cryogenic hydrogen laboratory had a power outage. The cryogenic hydrogen storage was no longer being cooled, therefore temperatures and pressures within the storage system started rising. There…
A hydrogen leak occurred at a tube bundle container at the loading and unloading bay of a PSA (Pressure Swing Adsorption) hydrogen production plant. During the hydrogen filling process, a worker in…
A hydrogen release and subsequent fire occurred at meter station of a pipeline transporting hydrogen to a refinery. Local refinery emergency response team responded and secured the area. The pipeline…
Release from a welding of a hydrogen transmission pipeline At 12:45 pm the operation control centre (OCC) recognised that a customer flow and pressure dropped significantly. At 13:28 the OCC made the…
At 17:30 on 5 may 2019, the pipeline operator was notified by a third party that there was a possible leak on its hydrogen pipeline, as identified by sound. Operator personnel arrived on the site at…