In an chlorine production plant, vented chlorine and hydrogen, auto ignited when the hydrogen concentration was allowed to exceed 5% and the mixture mixed with air. [Zalosh and Short, 1978]
An isolation failure in starter coil of the high voltage generator induced an electric arc to the hydrogen supply line, with consequent fire and melting of the line. [Zalosh and Short, 1978]
The fire was the consequence of the malfunctioning of a hydrogen compressor. This compressor was used to supply hydrogen to a reactor unit amining at increasing gasoline octane values.
Employees were refilling a rack of 15 hydrogen cylinders that were connected together on a steel pallet with railings. A leak developed at a valve and the pressurized hydrogen ignited. Operations…
The hydrogen release of a defect valve on the hydrogen supply line ignited due to an unknown cause. The fire caused the melting of soldered joint with consequence additional release of hydrogen at 6.…
A rupture of a tube in the furnace of an oil refinery caused it to loose 700 pounds of diesel and hydrogen resulting in a fire. The fire burned for a half hour with 30- to 40-foot (10 to 12 m) flames…
A hydrogen gas leak at an oil refinery ignited
The event occurred at the in the distillate hydrotreater unit of a refinery. This unit was using hydrogen to remove sulphur from a hydrocarbon feedstock. A 12-inch overhead pipe ruptured with a loud…
An explosion followed by a fire occurs in a refinery, originated by a hydrogen release at the hydrogen compressor.
A fire on a pipe providing hydrogen to a a refinery, causing a light injury to a worker. Company and local fire departments intervened. The were able to extinguish the fire in 2. 30 h.
The incident occurred at a hydrocracking unit, which had been shut down for maintenance. A fire occurred at a flange during the pressure tests before start-up. The fire resulted from ignition of high…
Firefighters used thermal imaging cameras to locate and extinguish a hydrogen fire at a silicon manufacturing plant.
The accident happened in a refinery unit, constructed ten years before. A pigtail ruptured in a steam reformer for the production of hydrogen, and caused a major fire, which destroyed most of the…
Due to the failure of a exhaust system, compressed hydrogen leaked into an area containing electrical components, with consequent fire. Leakage was allowed when exhaust system failed.
A fire was sparked by a hydrogen leak at a company producing composites for aerospace applications. The fire started in a pipe bringing hydrogen to the oven. It ignited likely from just the friction…
As the airship approached the docking mast, it performed a sharp turn to face into the wind, which was shifting. The engines were run at full speed astern for about a minute to slow the airship. Dust…
A release of compressed hydrogen and subsequent fire occurred during the transportation of a CGH2 trailer by means of a truck tractor. The tube trailer module contained 25 fully wrapped carbon filler…
Gaseous hydrogen release in generator caused by turbine vibrations [Zalosh and Short, 1978]
The fire developed an early morning on a hydrogen bus at a refuelling station for public transport. According to the bus company release, one bus was destroyed by fire suring refilling and the…
A flash fire enveloped a hydrogen compressor at a refinery.