HIAD Specific Application Supply Chain Stage: Hydrogen As Fuel


An explosion occurred at a hydrogen boiler of a chemical manufacturing plant producing hydrogen gas and other substances. A potential flow restriction in the feed line to a hydrogen-fired boiler…

The incident involves a gas booster provided by a manufacturer. This device is used in the experimental platform of the project to raise the pressure in pipelines from 60 to 80 barg (from 6 to 8 MPa)…
The event occurred in a university research building dedicated to the study of the take-off of space launchers . An operator gave the alarm during the hydrogen pressure pre-setting phase. he had seen…

Test facility H2 vent line exploded destroying about 150 feet of line. The flare stack was on at the time. [Ordin, NASA (1974)]

A hydrogen leak occurred on a hydrogen and fuel cells bus when in service. The bus driver received a low hydrogen level alarm [Note of HIAD validator: the nature of the alarm is not further…

The event occurred during a pressure testing of a LH2 pump discharge system. A weld joint failed at an internally tied bellows. The weld failed at 1100 psi (ca. 76 bar) while the test pressure…

The second stage of the Saturn V (S-II-T) was under full-duration static test, when one fire near LH2 valves of the LH2 tank and another in the engine area caused the automatic termination of the…

During a leak check of a flash point material testing chamber, the chamber was inadvertently over-pressurised with GH2. The glass port in the door burst, causing damage to the chamber and to the…

A hydrogen and fuel cells bus experienced a hydrogen detection alarm in a city centre. This triggered the evacuation of the immediate surroundings and the towing of the vehicle to the maintenance…

During the pre-launch checkout, a check valve failed in the "open" position and an accidental venting of liquid hydrogen occurred. The event caused an unscheduled check and replacement…

During the development test of a booster, a 3000 psig (ca. 205 bar) relief valve actuated at the normal line pressure releasing gaseous hydrogen, which ignited, resulting in an explosion which…

A car driving out from a private street hits the bus on the its right side just behind the rear tires
The vehicle was being driven in traffic at low speed when it was struck from behind by a full-size pickup which forced the fuel-cell vehicle forward into another pickup. No hydrogen was released and…

An unscheduled venting of a stage LH2 tank occurred, creating a hazardous condition for personnel and creating a potential explosion/ fire. [Ordin, NASA (1974)]