The compressor-turbine unit tripped while on on-load, due to a serious fire between alternator and one of the bearing. The failure of a generator slip ring and of the hydrogen seal caused the leak of…
The explosion occurred in the condenser area of a steam turbine, two hours after the unit tripped due to a stator earth fault. The stator earth fault had damaged two hydrogen cooler tubes, which…
Ejection of rotor wedge material lead to vibration induced failure of components, including hydrogen seals. Serious fire resulted from hydrogen leakage, which subsequently lead to an oil fire.…

The incident occurred at the power generator of a nuclear power plant, in a non-nuclear area of the plant. Although hydrogen was use in the system, it was not affected by the fire. Oil leaked at a…

The incident started at the unit removing CO2 from the process gas stream of a hydrocracking facility. (Catalysed Removal of Carbon Dioxide = Catacarb). Localized corrosion caused a pipe to fail and…
A sudden fire started at the hydrogen compressor of a refinery's hydrocracking unit.
A fire occurred at a refinery hydrocracker plant involving a gauge glass and hydrogen gas oil.
A hydrogen leak occurred from a low temperature valve on an acetic acid plant. The leak ignited and the resulting fire burned for about an hour. There was considerable media attention, particularly…
Hydrogen line at ammonia plant sprang a leak which ignited. Fire put out immediately causing no damage.

A fire occurred on top of a vent stack attached to a LH2 vessel. The ignition source was unknown but electrical storms in the vicinity may have been responsible. The flame was extinguished by…

Lightning caused fires at a plant near Hamburg after igniting a hydrogen mixture release through a ventilation pipe

This incident occurred at a at an electronics plant. While transferring of hydrogen from a compressed hydrogen tube trailer to stationary cylinder banks, a leak developed on the transfer hose and…

This incident occurred at CVD (coating vapour deposition) equipment. During operation, a vacuum pump for air discharging was turned on and by mistake silane and hydrogen gases were allowed to flow…

This incident occurred during the delivery of a hydrogen gas container to a customer site. When a worker turned the protective cap of the container, the valve handle turned together with the…

A truck loaded with 22 hydrogen cylinders pallets (370 litres each) was traveling on a national highway. While stopped at a traffic light, it was rear-ended by a large truck which damaged the…

A compressed hydrogen tube trailer was fully loaded and parked in the sun. The heat caused a pressure build-up, so that a burst disc failed prematurely venting hydrogen, which ignited. 13,360 cu…

A compressed hydrogen tube trailer was fully loaded and parked, when a rupture disc on one of the tubes failed. The escaping hydrogen ignited. 9583 cu ft were released. [Zalosh and Short, 1978]…

A trailer carrying compressed hydrogen tubes took fire at the rear while parked at a warehouse. The trailer-truck was carrying 130,000 standard cubic feet of hydrogen (300 kg), and was parked back…

Hydrogen leakage occurred on a pipe flange in an ammonia synthesis unit. A fire started immediately, which was taken under a control before the arrival of firefighters.
Explosion and fire in gasholder storing hydrogen in a thermal black plant