Skip to main content

HIAD Quality Indicator: 2


A released occurred at a hydrogen storage system. A small quantity of hydrogen gas leaked out of a pipe and caught fire. The danger of an explosion was averted by the safety crew who put out the fire…
Two employees were performing works on hydrogen piping (H2) in the chlorate production unit of a chemical plant when an ignited leak of H2 occurred. The operator initiated the emergency plan and…
Weld failure caused a fire involving a hydrogen pipe at a fertiliser ammonia plant. Source of ignition was auto ignition.
A fire occurred at a non-further specified indsutrial plant. The fire was the consequence of a liquid hydrogen leak from a joint between an isolating block valve and a relief valve on one of the…

The chain holding compressed hydrogen cylinders on a lorry broke. Probably the cylinders fell and due to the mechanical impact they released hydrogen resulting in a small fire [Zalosh and Short,…

Hydrogen enrichment of the gaseous phase in a rail tanker initiated an exothermic reaction between hydrogen and chlorine which in turn triggered fire of iron chloride.

A truck was transporting 35 compressed hydrogen cylinders (7 m3) to a sales office when it suddenly got a flat tire, causing the truck to overturn. The cylinders were thrown onto the road and gas…

The incident occurred while delivering seven compressed hydrogen cylinders to a customer site. The store employee had already removed four cylinders from the delivery truck and carried them…

A vehicle (non-further specified) carrying two hydrogen gas cylinders had to brake suddenly. The two cylinders tipped over, damaging the valve and causing hydrogen gas to leak out and ignite. The…

The incident affected a hydrogen gas purification unit of a chemical plant. A hydrogen release and ignition occurred at the joint between a pressure gauge attached to the inlet piping of an…

A fire occurred at a hydrogen refuelling station for buses. The incident was initially reported as an explosion due to a loud noise and vibrations felt in nearby buildings. However, subsequent…

Fire in a ammonia plant. The accident starts with a leak of a hydrogen-nitrogen mixture at the suctionflange of a compressor. The mixture ignites on contact with air and the fire spreads to an oil…
This incident occurred in a unit processing vegetable oils and fats. the explosion occurred in a hydrogenation facility, specifically where hydrogen is processed with a very high-pressure (400 bar).…
During repairs of a heat exchanger in a benzene plant, a mixed gas (methane and hydrogen) contained in the cold box attached to the exchanger leaked and caught fire from a welding spark. The…

The fire developed on one of two naphtha crackers for the production of ethylene. The rupture of the reactor made that the hydrogen, petroleum products (benzene) and the pyrophoric catalyst came…

In an chlorine production plant, vented chlorine and hydrogen, auto ignited when the hydrogen concentration was allowed to exceed 5% and the mixture mixed with air. [Zalosh and Short, 1978]
Fires and chain reactions involved more than 100 cylinders of hydrogen or other gases in a storage system. The fire lasted for more than 5 hours and the neighbourhood has been affected by flying…
A fire started in a refinery's gas oil desulphurization unit. The purpose of this unit is to separate sulphur from hydrocarbons and to do so, the latter are raised to 340°C in the presence of…
A jet fire occurred on the ammonia production unit, caused by a leak on a hydrogen pipe. Hearing a strange noise, an employee triggered the alarm after having discovered an ignited jet of hydrogen.…
Leak from faulty hydrogen seal ignited by short circuit between inboard slip ring and outboard slip ring radial lead connection. Hydrogen flame caused damage to brush gear assembly and inboard slip…