While driving on a highway, the driver of a CGH2 tube trailer was notified by another driver of the smoke coming from his trailer. The CGH2 tube trailer parked in a place considered safe,…

Safety slug in the vent pipe of a hydrogen trailer failed, damaging the pipe and causing a hydrogen leak. The following fire damaged several other trailers. [Zalosh and Short, 1978]

Failure of an 8 inch steel outlet pipe from a gas heater which ruptured and allowed hydrogen to escape with ensuing rapid ignition.

The event occurred during the disconnection of the hydrogen compressor for maintenance. Two deaths and three injured workers were the consequences. The cause(s) of the event are unknown .
A hydrogen leakage caught fire in the hydrogen compressor area of the continuous reforming unit. The reforming unit and the hydrocracking unit were immediately stopped. The hydrogen flow was cut off,…
A flash fire enveloped a hydrogen compressor at a refinery.
An incident occurred on a compressor at a refinery Fluid Catalytic Cracker Unit (FCCU) plant involving hydrogen. Source of ignition was hot surface.
A severe fire in a hydrogen compressor building in a an oil sands refinery reportedly started in a 1,500 psi (103 bar) lube oil system. Fire fighting was difficult because of 40 degrees F temperature…
A leak and fire occurred in a hydrogen compression section of a hydrocracker.
[NOTE of HIAD Validator: One source speak of a hydrogen gasometer, Spanish news speak in general of gas, others of natural gas or coal gas; considering the main product of the factory, it was chosen…
A hydrogen generator overheated during testing and started a small fire in a power plant.
A hydrogen line running to a furnace caught fire at a metals plant
The fire developed on the hydrogen production unit of a subcontractor in a plant producing metallic wire articles. The cause was a malfunctioning of the hydrogen unit. The production was stopped for…
A fire on one of the two hydrogen units at a gasoline refinery, hindering production.
the hazmat crews evacuated the workers at the Atmel building and established a safe zone. The crews used liquid nitrogen. The biggest danger was the possibility of an explosion.
[Note of HIAD Validator: this event description is unsatisfactory. Details on the prototype and the incident evolution are missing]. The incident affected a prototype light hydrogen vehicle in a…

A trailer-tractor carrying liquid hydrogen had been parked nearly 36 hours when the rupture disc blew. This resulted in a hydrogen plume which ignited. The fire continued until it ran out of fuel.…

A fire developed on a mathanation reactor. The methanation reactor vessel was found to be deformed and had a 3-4 inch rupture at a position corresponding to the top of the catalyst bed. It is thougth…

A fire in a first stage 'pygas' (pyrolysis of gasoline) hydrogenation of a naphtha cracker was caused by escape of a mixture of gasoline, hydrogen and nickel catalyst through a crack in…

A hydrogen leak occurred on a sintering furnace in a manufactory of uranium pellets. The event happened during the restart phase after a period of maintenance. The hydrogen ignited at the location of…