HIAD Facility - Operational Condition: Unknown


A fire on a pipe providing hydrogen to a a refinery, causing a light injury to a worker. Company and local fire departments intervened. The were able to extinguish the fire in 2. 30 h.
Due to unsealing of flange connection in a heat exchanger, hydrogen leaked and ignited. At 20 m height, under pressure of 0,25 MPa.
A fire broke out on a heat exchanger in a hydrocarbons plant. The cause of the fire was leakage of hydrogen.
Hydrogen was released into a diesel desulfurization unit, producing a 50-meter-long horizontal torch flame upon ignition. The unit was operating normally. Refinery firefighters responded quickly and…
Firefighters used thermal imaging cameras to locate and extinguish a hydrogen fire at a silicon manufacturing plant.

Safety slug in the vent pipe of a hydrogen trailer failed, damaging the pipe and causing a hydrogen leak. The following fire damaged several other trailers. [Zalosh and Short, 1978]

Failure of an 8 inch steel outlet pipe from a gas heater which ruptured and allowed hydrogen to escape with ensuing rapid ignition.

An incident occurred on a compressor at a refinery Fluid Catalytic Cracker Unit (FCCU) plant involving hydrogen. Source of ignition was hot surface.
A leak and fire occurred in a hydrogen compression section of a hydrocracker.
the hazmat crews evacuated the workers at the Atmel building and established a safe zone. The crews used liquid nitrogen. The biggest danger was the possibility of an explosion.

A fire in a first stage 'pygas' (pyrolysis of gasoline) hydrogenation of a naphtha cracker was caused by escape of a mixture of gasoline, hydrogen and nickel catalyst through a crack in…

Break of pipeline in oil cracker, resulting in a continuous release in partially confined atmosphere.

A dispenser hose failed at a hydrogen refuelling station. It ruptured with a sidewall burst, approximately 30 cm from the crimped end fitting. The hose had experienced a total of aproximately 300…

hydrogen gas cylinder explosion and subsequent fire in an electrical products company. 3 fatalities and 8 injuries. [Note of the validator: while the majority of the news report as cause the…

The explosion occurred when an operator opened a valve on the hydrogen network of the plant. The operator suffered from a burn in the forearm and two other employees were shocked by the pressure wave…

A hydrogen leak occurred in a CO (carbon monoxide) - hydrogen separation cold box of an acetic acid plant.

Hydrogen as carrier gas was provided to a reactor gas chromatograph by several compressed hydrogen bottles. The bottles emptied rapidly, but the loss of carrier gas could only be detected when the…

The event occurred at a pit furnace for metal component treatments. The hydrogen feed system for the furnace developed a leak, located on the hydrogen dryer inside a shack attached to a building. The…

Test facility H2 vent line exploded destroying about 150 feet of line. The flare stack was on at the time. [Ordin, NASA (1974)]

A leak occurred at the fill valve of a LH2 vessel. With the tank pressure at about 100 psi a leak was noticed. The area was cleared and the vessel was emptied by remote controls. [Ordin, NASA…