A leak occurs at a flange on a hydrogen gas transport. The load consisted of 9 cylinders of 80 m³ each. The producer of these cylinders decides to let it leak. No consequences to report.
A leak of 700 l of gaseous hydrogen was detected around on a connection of a rack of cylinders on a trailer truck, in aircraft plant (classified Seveso, lower tier).
This incident occurred on a hydrogen production device during the Great Hanshin Earthquake (Hyogo Prefecture Southern Earthquake). Hydrogen gas leaked from a pipe thread joint in a valve station. The…
A factory was evacuated after a tank began leaking hydrogen. No injuries were reported
Compressed hydrogen was released from a storage system due to the rupture of a Bourdon-type pressure gauge. [Zalosh and Short, 1978]

A faulty rupture disc failed prematurely releasing 750 cu ft of hydrogen (0. 2 kg). [Zalosh and Short, 1978]

The vacuum on a liquid hydrogen tanker was lost, resulting in a hydrogen release, both manually and through bursting of burst disc [Zalosh and Short, 1978]

A faulty burst disc on a liquid hydrogen tanker failed prematurely releasing 750 cu. ft. of of hydrogen. [Zalosh and Short, 1978]

Due to a loss of confinement of the inner shell of the liquid hydrogen tank, the vacuum of the external shell was destroyed. The reduced thermal insulation capacity of the shell caused evaporation…

The vent valve on a liquid hydrogen tanker vibrated open allowing a slight discharge hydrogen. [Zalosh and Short, 1978]

An unexplained loss of vacuum resulted in the release of all the transported hydrogen by manual venting and and opening of the relief valve. [Zalosh and Short, 1978]

A LH2 trailer was preparing to unload, when the pressure in the tank rose to about 165 psi (11. 3 bar) and caused the burst disc to rupture. The whole tank content was vented to atmosphere.

The rupture disc installed on a liquid hydrogen tank failed, in a plant producing organic chemicals, during the weekly shut down. The hydrogen ignited at the exit of the exhaust chimney. The fire and…
A liquid hydrogen leak occurs in a steel plant on a 42000 l tank of liquid hydrogen. A sealing coupling was installed to stop the leak.
Furnace tube leak caused excessive heat on H2 tube causing rupture [Zalosh and Short, 1978]
A hydrogen feed line ruptured without igniting at an oil refinery.

A release occurred from a high-pressure hydrogen storage vessel at a hydrogen refuelling stations. Immediately after detection, hydrogen was vented out as a safety measure. There was no injury,…

A leak occurred on the safety valve of a train wagon transporting liquid hydrogen. The train was composed of 10 wagons. The train was stopped on the railway several hours to allow depressurisation of…

A pipe of a hydrogen storage system (240 m³) breaks. The staff is evacuated and a perimeter of protection is put in place.

a hydrogen recycle compressor shut down unexpectedly, resulting in flaring activity with visible smoke.