Skip to main content

Explosion in a plant producing sodium (1244)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Explosion in a plant producing sodium

The event occurred in a plant specialised in the production of metallic sodium and lithium. The plant is clssified Seveso high tier. An explosion, with generation of smokes, took place in the unit treating the residues of metallic sodium by hydrolysis, which are very reactive and need to be passivated before disposal. This can happen in a two-stage process, burning followed by hydrolysis, or by direct hydrolysis. Due to a backlog of activity, the day of the event the residues were treated by direct hydrolysis, an operation which produces hydrogen. A shortcoming in the correct venting of the hydrogen was the cause of the explosion. It did not cause any injury, and the emergency was handled internally. The case appears a type of event occurring regularly on the site. Because of this, and the potential negative effect on public health and environment of toxic substances, the authorities decided to start an in-depth formal investigation.

Event Date
November 13, 2024
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The INTIATING CAUSE was an excessive production of hydrogen during the passivation of metallic sodium residues. The operations consisted predominantly in manual actions and obsolete equipment. This, in combination with highly reactive substances, regularl ycasued runaway reactions. On top of that, in the period of the incident, ther was a pressure to work out a backlog of materials. This made opting for the quicker but also more hazardous direct treatment of the residues by hydrolysis. Despite the absence of negative records on personnel health, the inspection found considerable shortcoming in safety management.

Facility Information
Application Type
Application
lithium, sodium production
Specific Application Supply Chain Stage
Components Involved

reactor

Storage/Process Medium
Location Type
Location description

DESCRIPTION OF THE PROCESS The role of the unit where the hydrogen is to remove the highly reactive residues that are removed either by burning followed by hydrolysis, or by direct hydrolysis. The burning stage produces sodium oxide by combustion in air: 4 Na + O2 -> 2 Na2O This makes the following hydrolysis less hazardous, because it avoid large production of hydrogen. Na2O + H2O -> 2 NaOH The direct hydrolysis process, if not properly controlled, presents a high risk of explosion due to the exothermic reaction between sodium and water, which generates hydrogen: 2 Na + 2 H2O -> 2 NaOH + H2

Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Property Loss (onsite)

low

Property Loss (offsite)

0

Post-event Summary

the roof of the electrolytic cell was damaged and had to be replaced.

Lessons Learned

The post-incident investigation could not perform a forensic analysis aiming at assessing quantities and sequence of event, because the affected unit was immediately brought back in a functioning state. Nevertheless, it identified several factors contributing to event. The waste treatment management exhibited structural weaknesses: (1) lack of traceability of treated batches, (2) manual sorting based on operator judgment, (3) potentially incomplete manual incineration, (4) outdated facilities, (5) significant pressure to reduce an existing stockpile of waste (to address this, the treatment capacity has already been doubled).

Event Nature
Emergency Action

The personnel knew what to do and a procedure was in place for this emergency. They waited for the natural extinguishing of the explosion, removed the residues and replaced the damage (the roof of the electrolytic cell). The unit was brought back online the following day. The local fire department was informed and present on site, but did not have to intervene.

Ignition Source
References
References

Bureau d’enquêtes et d’analyses sur les risques industriels (BEA-RI) "Rapport d’enquête sur l’explosion survenue au sein du site exploité par la société MSSA à Saint-Marcel (73) le 10 septembre 2024", N° : MTE-BEARI-2025-09 (2025), available at https://www. igedd. developpement-durable. gouv. fr/IMG/pdf/bea-ri_rapport_mssa_vdiff_cle2162d1. pdf (accessed January 2026)