Skip to main content

Explosion in a electrical products plant (673)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Explosion in a electrical products plant

An employee was attempting to re-weld a lifting point on a brazing furnace cover. He was using a tungsten inert gas (TIG) welding machine to build up an attachment point on the cover when an explosion occurred. Its force lifted the furnace cover and propelled it against the employee. There were no witnesses to the incident. The furnace had apparently not been evacuated completely of gaseous hydrogen, and this may have triggered the explosion.
Event Date
October 28, 1996
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The furnace had apparently not been evacuated completely of gaseous hydrogen, and this may have triggered the explosion.
Facility Information
Application
brazing furnace
Specific Application Supply Chain Stage
Components Involved
brazing furnace, cover
Storage/Process Medium
Location Type
Operational Condition
Pre-event Summary

During welding works

Consequences
Number of Injured Persons
1
Number of Fatalities
0
Post-event Summary

Medium injuries.

Lessons Learned
Too less is known on the specific furnace application and the accidental sequence, to deduce a lesson. If the assumed cause is correct, a necessary step before starting any type of maintenance or repairing work is to purge the furnace with nitrogen and to verify the concentration with a detector.
Event Nature
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

U. S. Department of Labor Occupational Safety & Health Administration OHSA, Inspection: 125571786, https://www. osha. gov/pls/imis/establishment. inspection_detail?id=125571786, (accessed November 2020)