Skip to main content

Document library

PUBLICATION · Technical Report

Safety Codes and Standards Review and Gap Analysis for Applicability to Hydrogen Rail Refueling, Defueling, Maintenance, and Storage

Hydrogen-powered locomotives may present an alternative to diesel for achieving transportation-related decarbonization, energy security, and resilience goals. As an emerging technology, hydrogen locomotives may not have adequate representation in current safety codes and standards. NFPA 2 and other appropriate codes and standards were reviewed to identify technical gaps in the code for hydrogen rail defueling, refueling, maintenance, and storage. Several technical gaps pertaining to setback distances, allowable quantities, ventilation rates, and grounding have been identified.

PUBLICATION · Technical Report

Assessment of Potential Failure Modes and Effects for On-Board Components for Hydrogen-Powered Locomotives

Hydrogen fuel sources offer alternatives to conventional fuels in the rail transportation industry. Hydrogen powered locomotive designs utilizing either a fuel cell or an internal combustion engine can make migration to alternative fuels possible for rail transportation. Codes and standards are still in development for rail application of hydrogen and safety risks must be assessed for hydrogen locomotive applications. This report utilizes a failure mode & effects analysis framework to help qualitatively understand possible risks from a hydrogen locomotive system.

PUBLICATION · Technical Report

Validation of HyRAM+ Version 5.1 Physics Models

The Hydrogen Plus Other Alternative Fuels Risk Assessment Models (HyRAM+) software has seen various improvements and additional physics capabilities since validation against experimental data was last published for HyRAM v3.1. Notably, HyRAM+ now includes four models allowing for the calculation of overpressure resulting from vapor cloud explosions from unconfined jet releases. As with the previous HyRAM validation report, validation data was gathered from available published literature and tested against HyRAM+ capabilities.

PUBLICATION · Technical Report

Large-Scale Hydrogen Storage Cyber Risk Assessment

Hydrogen storage systems are becoming more widely deployed throughout the country, and as their presence continues to grow, it is possible that individual and interconnected systems will be exposed to cyber-attacks. These events can cause physical and financial harm to employees, people in the vicinity, and to the company that owns the facility.

PUBLICATION · Technical Report

Example Implementation for Cascading Leaks in Large-Scale Hydrogen Storage Risk Assessments

Leaks in a hydrogen system can have destructive effects on other components within the system, leading to cascading leaks. The risk of cascading leaks is not currently quantified in many existing risk frameworks, but the prevalence of cascading failures in historical hydrogen facility accidents necessitates further study. A method for quantifying the probability, frequency, and risk of cascaded leaks is proposed.

PUBLICATION · Technical Report

Evaluation of Hydrogen Storage Quantity Limits for Safety Requirements

As hydrogen storage facilities increase in size and capacity, it may be necessary to evaluate codes and standards that regulate hydrogen, especially in relation to allowable aggregate quantities. Existing regulations for other substances with comparable hazards such as oxygen, natural gas, and petroleum were reviewed; most fuels do not have aggregate quantity limits despite sometimes having individual tank capacity restrictions or limits for certain non-industrial, indoor, or small-scale applications. This precedent suggests that specifying a hydrogen quantity limit may not be necessary.

PUBLICATION · Technical Report

Quantitative Risk Assessment for Hydrogen-Powered Locomotive Refueling

Hydrogen powered locomotives are being explored to reduce emissions in rail applications. The risks of operations like refueling should be understood to ensure safe environments for workers and members of the public. Sensitivity analyses were conducted using HyRAM+ to identify major drivers of risk and compare effects of system parameters on individual risk. The consequences of jet fires from full-bore leaks dominated the risk, compared to explosions or smaller leaks.

PUBLICATION · Progress Report

Study Investigating the Safety of Hydrogen as Fuel on Ships

This report is developed as a part of the project “EMSA study investigating the safety of hydrogen as fuel on ships”. The overall objective of the project is to carry out a structured set of safety assessments and reliability analyses,
delivering a Guidance document addressing ships using hydrogen as fuel. The purpose is to assist the industry and the regulators towards a safe and harmonised deployment of this relevant technology that could demonstrate an important step towards decarbonisation of the sector.

PUBLICATION · Technical Report

Quantitative risk assessment examples for underground hydrogen storage facilities

Hydrogen energy storage can be used to achieve goals of national energy security, renewable energy integration, and grid resilience. Adapting underground natural gas storage facility (UNGSF) infrastructure for underground hydrogen storage (UHS) is one method of storing large quantities of hydrogen that has already largely been proven to work for natural gas.

Disclaimer- The documents and references herein are for information purposes only and should not be construed as endorsement by the Hydrogen Safety Panel.