Water electrolyser explosion
The incident occurred during the verification operation of a water electrolyser, a high-pressure PEM prototype. This prototype was part of a demonstration project for a hydrogen refuelling station with onsite hydrogen production. An abnormal reaction took place in the electrolytic cells, which caused an explosion and a fire. The temperature was estimated at 400C and the pressure at a value above 200 MPa. The reaction escalated by involving the oxygen separation tanks and the vents. The electrolysis cell burned down, the pipes of the oxygen circuit burst and the peripheral equipment were scattered all over the facilities. There was no injury. The analysis of the incident differ slightly between sources (see References): they agree on the fact that the cause was an abnormal reaction inside the electrolytic cells. They agree in identifying the first cause of the reaction either (i) in the exposure of the titanium electrode in to oxygen, or (ii) in the cross diffusion of hydrogen into oxygen forming an explosive mixture. They differ however in assuming which one of the two reactions started first. The voltage to the generator was shut down in an early phase of the incident. Later on, also the water recirculation pump was shutdown. Nevertheless, the pressure inside the cell kept raising from a nominal value of 40 MPa to a value estimated to more than 100 MPa, despite the activation of the safety valve.
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments
The INITIATING cause was probably the reaction between oxygen and the titan electrode, or the re-combination of oxygen and hydrogen. The ROOT CAUSE was a ill-design, due to lack of in-depth knowledge of material behaviour in a high-pressure electrolytic cell. This was further worsened by a badly performed risk assessment, and ill-functioning project governance: the University was employing part-time professors in charge of the safety management. Since the safety manager and safety technology manager, were not covering full-time positions, it was difficult to actually carry out their duties as required by law.