Skip to main content

Road incident of a LH2 tanker (1008)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Road incident of a LH2 tanker

A tanker-tractor carrying liquid hydrogen overturned and lost vacuum insulation. The hydrogen boiled and vented, but there was no ignition. The potential for fire or explosion, however, led to precautions that did cause considerable disruption: the interstate highway where the accident occurred was closed and nearby homes and businesses were evacuated.
Event Date
August 25, 1987
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments

INITIATING cause was a traffic accident. In absence of information on drivers and driver behaviours, the ROOT CAUSE can be attributed generically to a human error (wrong maneuvre)

Facility Information
Application
LH2 tanker
Specific Application Supply Chain Stage
Components Involved
vacuum thermal insulation
Storage/Process Medium
Storage/Process Quantity
3824
Actual Pressure
1
Design Pressure
1
Location Type
Operational Condition
Pre-event Summary

The sources do no specify if the tanker was full. It can be nevertheless understood from the statement that the hydrogen boiled off and was release that the tanker was still liquid hydrogen to be delivered to a customer (on their return travel, the LH2 tankers contain normally only could gaseous hydrogen).

Consequences
Number of Injured Persons
0
Number of Fatalities
0
Post-event Summary

no consequence, but local evacuation

Event Nature
Emergency Action
The interstate highway was closed and nearby homes and businesses were evacuated.
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

Ringland, Safety Issues for Hydrogen Powered Vehicle, SANDIA REPORTSAND94-8226 https://www. osti. gov/servlets/purl/10136126 (accessed October 2025)

Incident I-1987090240 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages&PortalPath=%2Fshared%2FPublic%20Website%20Pages%2F_portal%2FHazmat%20Incident%20Report%20Search (accessed September 2024)