Skip to main content

CGH2 tubes falling from trailer (291)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

CGH2 tubes falling from trailer

A trailer was transporting 35 tubes of compressed hydrogen (7 m3), when five of them fell, breaking the valves and releasing gas, which ignited on three of them. The caps designed to prevent the tubes from falling had not been attached before starting the journey.

Event Date
July 6, 1976
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The INITIATING CAUSE was the falling of compressed hydrogen tubes from a trailer. The KHK report attributed the ROOT CAUSE to “mishap”, without however clarifying further if this was a human error (failing to follow the procedures) or a lack of clarity of the procedures.

Facility Information
Application
CGH2 tube trailer
Specific Application Supply Chain Stage
Components Involved

valves

Storage/Process Medium
Storage/Process Quantity
100
Location Type
Operational Condition
Pre-event Summary

The trailer was transporting 35 tubes. Assuming that the 7 m3 value provided by the KHK report refers to the total water capacity, a total of 100 kg of transported hydrogen can be calculated, further assuming a pressure of 200 bar.

Consequences
Number of Injured Persons
0
Number of Fatalities
0
Event Nature
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

High Pressure Gas Accident Cases Database of the KHK (High Pressure Gas Safety Association): https://www. khk. or. jp/public_information/incident_investigation/hpg_incident/incident_db. html (accessed May 2025)