Skip to main content

Leak from a CGH2 tube trailer (1215)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Leak from a CGH2 tube trailer

A leak occurred on a tube trailer while parked at a rest area of a highway. The trailer was very probably full. Hearing a hissing noise, the driver concluded that hydrogen was leaking from of the trailer and alerted the authorities. Emergency services and police intervened and evacuated the rest area, which remained closed for about eight hours. The truck was decoupled from the trailer. An expert of the hydrogen shipping company arrived on site, and employees of a nearby refinery assisted with hydrogen detecting equipment. Specially trained firemen wearing breathing apparatus attended the scene and performed a controlled release of the hydrogen. A source mentioned by the online news reported that the leak was suspected to come likely form a crack on the supply line.

Event Date
March 12, 2025
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments

The INITIATING CAUSE was a release from a tube trailer, possibly from a crack on the supply line. The ROOT CAUSE is unknown.

Facility Information
Application
CGH2 tube trailer
Specific Application Supply Chain Stage
Components Involved

supply line

Storage/Process Medium
Storage/Process Quantity
950
Actual Pressure
30
Design Pressure
30
Location Type
Location description

DESCRIPTION OF THE TRAILER The news do not provide information on the configuration and operative data of the tubes. Very probably this was a trailer with vertically aligned tubes of type IV (carbon fibre reinforced plastic wrapped composites). The version affected inthis eventwas probably cosnsiting of 127 tubes (44,450l), at a working pressure 300bar. The payload was 11,100 m³ of hydrogen (950 kg). The video shows firemen searching for the leak inside the main body of hte trailer. From this, it could be deducced that th leak occurred at one of the piping connecting the individual tubes to the main line to the rear cabinet.

Operational Condition
Pre-event Summary

According to the news, the driver discovered the leak by hearing a hissing sound when parked at a rest station. If this is confirmed, it means that the trailer was leaking already before, when travelling, and that it is unknown for how long.

Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Property Loss (onsite)

0

Post-event Summary

No injury, property loss or environmental impact. Only the whole hydrogen cargo was released to the atmosphere

Event Nature
Emergency Action

Emergency services and police intervened and evacuated the rest area, was evacuated and remained closed for about eight hours. The truck was decoupled from the trailer. An expert of the hydrogen shipping company arrived on site, and employees of a nearby refinery assisted with hydrogen detecting equipment. Specially trained firemen wearing breathing apparatus attended the scene and performed a controlled release of the hydrogen.

Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Grafschafter Nachricht on YouTube https://www. youtube. com/watch?v=CU4H3UOBbxU (accessed September 2025)

News from fire department Lohne https://www. ortsfeuerwehr-lohne. de/einsaetze/ansicht/41790/h3x-gefahrgut. html 9accesed November 2025)