Skip to main content

Detonation of hydrogen in vent stack (369)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Detonation of hydrogen in vent stack

During the pump operation of a liquid hydrogen tanker, the vent valve was opened rapidly and the hydrogen detonated above the vent stack. The rapid valve opening was aimed at initiating a good pumping in the LH2 pump-vaporizer system. The vent valve was then closed, but the stack continued to flow hydrogen, which burned. The tanker pressure was 16 psig (ca. 1. 1 bar). [Ordin, NASA (1974)]

Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

Apparently, the hydrogen release was intentional, but it ignition occurred due to the rapid opening of the vent valve. Following the detonation, the fire continued because the flap valve on the vent did not make a tight seal. The Teflon gasket was found scorched. According to the report, the vent stack was not purged allowing for a H2- air mixture in the stack. It is unclear if purging was foreseen by the procedure.

Facility Information
Application
LH2 tanker
Specific Application Supply Chain Stage
Components Involved

vent valve, stack

Location Type
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Event Nature
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Mishap no 17 in P. L. Ordin, Review of hydrogen accidents and incidents in NASA operations, 1974, NASA TM X-71565 https://ntrs. nasa. gov/citations/19740020344