Conventional fire on a CGH2 trailer
A CGH2 tube trailer-tractor was travelling to deliver hydrogen to a customer, when a fire developed on right side of the tractor around the rear of the hood and passenger side door. Very quickly the entire power unit was engulfed in flames. The driver called 911. The highway was closed. Approximately 30 minutes later, the fire had spread to the tractor drive tires on the passenger side causing extreme heat on the bottom tubes of the trailer. Hydrogen began to leak and ignited. The fire continued to burn slowly until customer personnel lowered the pressure in the tube, which stopped the flow of gas and the fire self-extinguished. The burst disk did not appear to have failed. It was therefore presumed that the seal between the bull plug and the cylinder end melted and caused the leak. The units were released to a towing company approximately 7 hours later.

The INITIATING CAUSE was a conventional fire from tractor components (similar incidents reported the brakes as the source of the over-heating). The ROOT CAUSE is unknown, because the result of the investigation is not available. However, the fact that the burst discs do not appear having failed indicates that the the pressure inside the tubes was not affected by the heat. It has been preliminary concluded that a component part of the pressure control system of the tube failed under fire, very likely the bull plug of the tubes. It indicate an inadequate safety design