Skip to main content

CGH2 tube trailer leaking (1252)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

CGH2 tube trailer leaking

The driver of a hydrogen tube trailer stopped for a rest break and heard an audible leak from the composite tube mounted on the trailer. Local Fire department, medial emergency services and the police responded. They established an 800-ft evacuation area for several hours. A technician of the shipping company responded and inspected on scene. The leak ceased without ignition (unclear if stopped by itself, or because of a manual intervantion). Later, the unit was returned to shipping company's facility, where it was emptied, inspected by tubes manufacturer and later sent to manufacturer plant for repair.

Event Date
September 5, 2025
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments

The event was probably due to the reaction between the residues in the extraction ducts and the caustic soda, which caused a release of hydrogen. A similar event had occurred at the site seven years earlier, which had been attributed to the excessive presence of metallic dust in the unit, which in contact with water produced hydrogen (See HIAD_1250 based on ARIA 50150). At that time, several improvements were introduced to the treatment unit, to be able to monitor and detect earlier the conditions under which hydrogen is accidental produced.

Facility Information
Application
CGH2 tube trailer
Specific Application Supply Chain Stage
Storage/Process Medium
Storage/Process Quantity
1150
Actual Pressure
18
Design Pressure
27
Location Type
Location description

Trailer technical specification (in SI): Nominal pressure = 275 bar Total capacity = 1,156 kg Configuration = 8 tubes, organised in 2x2 plus 2x2 arrays For one single tube: Nominal content of one tube= 135 kg Content in one tube before leak = 87 kg Content in one tube after leak = 66 kg

Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Property Loss (onsite)

low

Post-event Summary

A limited amount og hydrogen was lost.

Event Nature
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Incident I-2025100048 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages&PortalPath=%2Fshared%2FPublic%20Website%20Pages%2F_portal%2FHazmat%20Incident%20Report%20Search (accessed September 2024)

My Wabash Valley news https://www. mywabashvalley. com/news/local-news/breaking-hydrogen-leak-in-casey-il-prompts-evacuation/ (accessed December 2025)

WCIA news on Youtube. com https://www. google. com/search?q=2025%2C+September+5%2C+hydrogen+trailer+release+in+Mach+1%2C+939+IL-49%2C+Casey%2C+IL%2C&oq=2025%2C+September+5%2C+hydrogen+trailer+release+in+Mach+1%2C+939+IL-49%2C+Casey%2C+IL%2C&gs_lcrp=EgRlZGdlKgYIABBFGDkyBggAEEUYOTIICAEQ6QcY_FUyBwgCEOsHGEDSAQkzOTU4MWowajmoAgCwAgA&sourceid=chrome&ie=UTF-8#fpstate=ive&vld=cid:5940d0c8,vid:_Su1WPXhwYw,st:0 (accessed December 2025)