CGH2 tube trailer leaking
The driver of a hydrogen tube trailer stopped for a rest break and heard an audible leak from the composite tube mounted on the trailer. Local Fire department, medial emergency services and the police responded. They established an 800-ft evacuation area for several hours. A technician of the shipping company responded and inspected on scene. The leak ceased without ignition (unclear if stopped by itself, or because of a manual intervantion). Later, the unit was returned to shipping company's facility, where it was emptied, inspected by tubes manufacturer and later sent to manufacturer plant for repair.
Event Date
September 5, 2025
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes

The event was probably due to the reaction between the residues in the extraction ducts and the caustic soda, which caused a release of hydrogen. A similar event had occurred at the site seven years earlier, which had been attributed to the excessive presence of metallic dust in the unit, which in contact with water produced hydrogen (See HIAD_1250 based on ARIA 50150). At that time, several improvements were introduced to the treatment unit, to be able to monitor and detect earlier the conditions under which hydrogen is accidental produced.