Skip to main content

ASME Case 3078-1 Rules for Gasketed Electrochemical Cell Stacks for Electrolysis

ASME Case 3078-1 Rules for Gasketed Electrochemical Cell Stacks for Electrolysis

Region/Organization
Scope

The rules in this Case cover the minimum requirements for materials, design, testing, and documentation of planar geometry gasketed electrochemical cell stacks (ECS) for electrolysis within the scope described in Section VIII, Division 1, U-1.

For ECS, the inside diameter dimension referred to in U-1(c)(2)(-i) shall be the largest distance measured between the inner edges of the sealing surfaces in the cross section of the ECS. For an ECS with rectangular or other non-circular cross section, the inside diameter shall be the longest diagonal.

These rules cover the gasketed ECS and their components but are not intended to limit the configurations or details to those illustrated or otherwise described herein. Designs that differ from those covered in this Case shall be in accordance with the provisions in U-2(g).

These rules apply to gasketed ECS that have a maximum design temperature below the boiling point of the electrolyte, but in no case exceeding 250°F (121°C). ECS that are installed in an external vessel are exempted from the rules in this Case, provided that the external vessel meets the applicable rules of Division 1 unless exempted under U-1. The MAWP of the external vessel shall be no less than the design pressure of the ECS.

The external vessel design shall consider abnormal pressures due to deflagration in UG-22(i) and Nonmandatory Appendix H for possible hydrogen and oxygen leaks from internal ECS.

This Case does not address the process and electrical safety requirements of ECS. These requirements are commonly found in other applicable safety standards such as CSA/ANSI B22734:23 or ISO 22734:2019.

Note: This Code Case will be integrated into Section VIII directly with the next revision (2027).

Status Explanation

Published 2024. Available at www.asme.org