Hydrogen Composite Tube Trailer Leak Response Actions

Hydrogen Composite Tube Trailer Leak Response Actions

Is there consensus guidance for operations and service personnel on when to step back from a hydrogen composite tube trailer after a leak is detected and allow the system to vent down before taking further action?

There is no currently recognized consensus on a guideline that prescribes whether operators or service personnel should back away from a leaking hydrogen trailer and allow it to fully vent, or whether they should take other actions.  Much will depend on the type of trailer, whether the trailer is enclosed, the size of the leak, and whether the leak is readily accessible.  Actions might include, but are not limited to, opening the trailer door to access the leak if it's enclosed, depressurizing the trailer externally to stop the leak, or using a detector to understand the severity of the leak and the extent of the flammable cloud. In practice, the response is typically defined by the equipment owner, trailer provider, or operating organization through their own procedures and training.  It may also depend on where the trailer is located and direction provided by emergency responders if they are involved.

Hydrogen tube trailers present unique operational challenges compared to stationary systems. Because they are transported frequently, they are subject to vibration and other external influences that can increase the likelihood of leaks over time.  In addition, trailers are often in public or quasi-public areas which are not fenced from third parties, leading to other considerations.  Maintenance activities can also be difficult due to the configuration of the equipment and the need to keep the trailer roadworthy and in service. While U.S. Department of Transportation (DOT) regulations generally require each vessel to have a shutoff valve leading to the manifold, these systems do not always incorporate the type of double block and bleed isolation arrangement commonly found in stationary hydrogen installations. As a result, the ability to completely isolate the hydrogen gas may be limited. There are also many fittings and connections on trailers that cannot be isolated with the DOT mandated shutoff valves, even if automated.  

Operational responses to a detected leak often depend on the specific circumstances and the purpose of the work being performed. In some cases, operators may isolate individual vessels if possible; in others, depressurizing or purging the system may be the safer option. Many decisions ultimately rely on established procedures and the judgment of trained personnel. For example, if a leak is suspected within an enclosure, even actions such as opening the trailer door must be considered carefully, since doing so could introduce an ignition source (e.g. from the chains on the trailer door) while placing the operator in close proximity to a potentially hazardous atmosphere. Additionally, the size of the leak matters. For example, with larger, audible leaks, operators may choose to stand back and allow the leak to subside. For smaller leaks detected by monitoring equipment, it may be possible to take corrective action.

Given these factors, there is growing recognition that the industry could benefit from consensus best practices regarding leak response, isolation strategies, evaluating a safe stand-off distance, and developing vent-down approaches for mobile hydrogen systems.

The Hydrogen Safety Panel (HSP) is working to compile several related white papers, including:

·       Hazards and Mitigations Associated with the Delayed Ignition of Hydrogen Releases

·       Lessons Learned and Best Practices for High Pressure Hydrogen Transport Trailers

·       Design Considerations for Hydrogen Enclosures

More information on the risks and considerations for hydrogen transport trailers can be found in these papers, to be released in the coming months.