Where does ASME B31.3 address the distinction between pressure-relieving devices for piping applications and those for pressure vessels, particularly with respect to the acceptability of pop-acting vs proportional-action valves?

 

Unfortunately, the requirements for pressure-relieving devices in ASME B31.3 (2024 edition) are currently complicated by changes made to the ASME Boiler and Pressure Vessel (BPV) Code. The key paragraph is B31.3, §322.6.3, Pressure-Relieving Devices. This paragraph refers to BPV, Section VIII, Division 1 for many of the applicable requirements. However, those requirements were removed from Section VIII beginning with the 2021 edition. As a result, understanding the current B31.3 references requires consulting the 2019 or earlier editions of Section VIII.

Beginning with the 2021 edition, the requirements for pressure-relief devices were moved from Section VIII to Section XIII. The B31.3 Section Committee has been working to revise the B31.3 requirements to align with this change, but a corresponding revision has not yet been completed.

When the pressure-relief-device requirements were contained in Section VIII, they were located in UG-125 through UG-136. B31.3 referred users to Section VIII but, importantly, did not incorporate all of those UG paragraphs in their entirety.

The key provision in B31.3 is §322.6.3. It specifies that pressure-relieving devices:

"…shall be in accordance with the BPV Code, Section VIII, Division 1, UG-125(c), UG-126 through UG-128, and UG-132 through UG-136, excluding UG-135(e) and UG-136(c)."

As a result, pressure-relieving devices used for piping systems are not required by B31.3 to meet all of the same requirements that Section VIII establishes for pressure vessels.

One particularly important distinction is that B31.3 does not reference UG-129. UG-129 specifically addressed marking requirements, including the requirement for applicable pressure-relief valves to bear the ASME "UV" Code Symbol Stamp. Because UG-129 is not among the Section VIII provisions incorporated by B31.3 §322.6.3, B31.3 does not require piping pressure-relief valves to bear the ASME UV Code Symbol Stamp.

This permits a broader range of pressure-relief valves to be used in B31.3 piping applications, including "safety relief valves," which can be either pop-acting or proportional-acting. In nearly all situations, a proportional-acting valve offers advantages over a pop-acting valve by significantly reducing the potential for valve chatter. Proportional operation can also largely resolve concerns associated with valves having substantially greater capacity than required, because flow through the valve can more closely correspond to the relieving demand rather than immediately reaching the valve's full rated capacity.