PUBLICATION · Journal Article

Very lean hydrogen vapor cloud explosion testing

Hydrogen is a key energy carrier for modern society. The breaking of the hydrogen bonds within traditional hydrocarbon molecules has been the primary mode of energy utilization since the industrial revolution. An increased focus on “net-zero” greenhouse gas emissions, specifically carbon dioxide and methane, has resulted in a global push for lower carbon energy vectors, including pure hydrogen.

PUBLICATION · Technical Report

Hydrogen-Ready Appliances Assessment Report

State policy targets on greenhouse gas emission reductions and other decarbonization initiatives are creating a movement toward low or zero-carbon gases and fuels. Given its versatility as an energy carrier and its potential for use in a broad range of applications, hydrogen is gaining in popularity, and natural gas providers are looking at integrating it into their networks.

PUBLICATION · Technical Report

Technical Justifications for Liquid Hydrogen Exposure Distances

The previous separation distances in the National Fire Protection Association (NFPA) Hydrogen Technologies Code (NFPA 2, 2020 Edition) for bulk liquid hydrogen systems lack a well-documented basis and can be onerous. This report describes the technical justifications for revisions of the bulk liquid hydrogen storage setback distances in NFPA 2, 2023 Edition. Distances are calculated based on a leak area that is 5% of the nominal pipe flow area.

PUBLICATION · Journal Article

Liquid hydrogen storage system for heavy duty trucks: Configuration, performance, cost, and safety

In this work, we investigate the potential of liquid hydrogen storage (LH2) on-board Class-8 heavy duty trucks to resolve many of the range, weight, volume, refueling time and cost issues associated with 350 or 700-bar compressed H2 storage in Type-3 or Type-4 composite tanks. We present and discuss conceptual storage system configurations capable of supplying H2 to fuel cells at 5-bar with or without on-board LH2 pumps. Structural aspects of storing LH2 in double walled, vacuum insulated, and low-pressure Type-1 tanks are investigated.

PUBLICATION · Technical Report

Benchmark Comparison of HyRAM and ALDEA Software for Hydrogen Release Behavior

There are several different calculation approaches and tools that can be used to evaluate the risk of hydrogen energy applications. A comparative study of Air Liquide’s ALDEA (Air Liquide Dispersion and Explosion Assessment) tools suite and Sandia’s HyRAM (Hydrogen Risk Assessment Models) toolkit has been conducted. The purpose of this study was to understand and evaluate the differences between the two calculation approaches, and identify areas for model improvements. There were several scenarios examined in this effort regarding hydrogen release dynamics.

PUBLICATION · Technical Report

Hydrogen Plus Other Alternative Fuels Risk Assessment Models (HyRAM+) (Technical Reference Manual V.4)

The HyRAM+ software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen, methane, and propane infrastructure and transportation systems. HyRAM+ is designed to facilitate the use of state-of-the-art science and engineering models to conduct robust, repeatable assessments of safety, hazards, and risk. HyRAM+ includes generic probabilities for equipment failures, probabilistic models for the impact of heat flux on humans and structures, and experimentally validated first-order models of release and flame physics.

PUBLICATION · Technical Report

Refueling Infrastructure Scoping and Feasibility Assessment for Hydrogen Rail Applications

The feasibility and component cost of hydrogen rail refueling infrastructure is examined. Example reference stations can inform future studies on components and systems specifically for hydrogen rail refueling facilities. All of the 5 designs considered assumed the bulk storage of liquid hydrogen on-site, from which either gaseous or liquid hydrogen would be dispensed. The first design was estimated to refuel 10 multiple unit trains per day, each train containing 260 kg of gaseous hydrogen at 350 bar on-board.