Skip to main content

Document library

PUBLICATION · Technical Report

HyRAM V1.1 User Guide

Hydrogen Risk Assessment Models (HyRAM) is a software toolkit that provides a basis for quantitative risk assessment and consequence modeling for hydrogen infrastructure and transportation systems. HyRAM integrates validated, analytical models of hydrogen behavior, statistics, and a standardized QRA approach to generate useful, repeatable data for the safety analysis of various hydrogen systems. HyRAM is a software developed by Sandia National Laboratories for the U.S. Department of Energy.

PUBLICATION · Research Paper

Ammonia and Hydrogen Vapor Cloud Explosion Testing (A Tale of Two Gases)

Ammonia and hydrogen represent opposite ends of the spectrum with regard to the potential blast loading resulting from an accidental vapor cloud explosion (VCE), although many in industry have expressed doubts as to whether either of these fuels actually pose a VCE hazard. Ammonia is some-times discounted as a VCE hazard due to the perceived difficulty in igniting an ammonia-air mixture and/or because of its low laminar burning velocity. Hydrogen is sometimes discounted as a VCE hazard due to the ease with which a hydrogen-air mixture can be ignited and/or because of its buoy-ancy.

PUBLICATION · Technical Report

Hydrogen Equipment Certification Guide: Listing, Labeling, and Approval Considerations

The purpose of this guide is to assist users of codes and standards that apply to hydrogen application and use in understanding and applying the approval, certification, listing, and labeling provisions of the codes and standards, in any application where the required certification, listing, and labeling of services, methods, or equipment has not yet been established or achieved.  

PUBLICATION · Technical Report

Abusive Testing of Proton Exchange Membrane Hydrogen Fuel Cells

In collaboration with Parker Hannifin Corporation, the Fire Safety Branch of the FAA conducted testing to evaluate the effects of three potential failure conditions of hydrogen proton exchange (or polymer electrolyte) membrane fuel cell stacks supplied by Nuvera Fuel Cells. The three conditions examined were a loss of coolant to the stack, short circuit, and a crossflow condition.

PUBLICATION · Research Paper

Evaluation of flammability limits of H 2 /O 2 /N 2 mixtures in conditions relevant to nuclear waste transportation

The aim of the present work is to assess the risk of explosion in closed containments used for the transportation of nuclear materials or nuclear waste. Indeed, it is very well known that hydrogen can be produced due to (i) the radiolysis of different materials within the containment, (ii) the thermal decomposition of mainly the organic part in the containment. Since hydrogen has a very low ignition energy and a very wide flammability domain, it is important to determine the risk of ignition of the subsequent mixture produced by the aforementioned mechanisms.

PUBLICATION · Technical Report

Hydrogen Embrittlement - NASA

This Technical Memorandum was originally prepared as an Annex on the topic of Hydrogen Embrittlement for the AIAA Guide to Safety of Hydrogen and Hydrogen Systems (G-095-2004), then in revision [1]. The Guide establishes a uniform NASA process for hydrogen system design, materials selection operation, storage and transportation, and represents a broad collection of aerospace acumen.

Disclaimer- The documents and references herein are for information purposes only and should not be construed as endorsement by the Hydrogen Safety Panel.