Skip to main content

Document library

PUBLICATION · Technical Report

Study of Hydrogen Fuel Cell Technology for Freight Rail Propulsion and Review of Relevant Industry Standards

Alternatives to conventional diesel electric propulsion are currently of interest to rail operators. In the U.S., smaller railroads have implemented natural gas and other railroads are exploring hydrogen technology as a cleaner alternative to diesel. Diesel, battery, hydrogen fuel cell, or track electrification all have trade-offs for operations, economics, safety, and public acceptability. A framework to compare different technologies for specific applications is useful to optimize the desired results.

PUBLICATION · Conference Paper

Analysis to support revised distances between bulk liquid hydrogen systems and exposures

The minimum distances between exposures and bulk liquid hydrogen listed in the National Fire Protection Agency’s Hydrogen Technology Code, NFPA 2, are based on historical consensus without a documented scientific analysis. This work follows a similar analysis as the scientific justification provided in NFPA 2 for exposure distances from bulk gaseous hydrogen storage systems, but for liquid hydrogen.

PUBLICATION · Technical Report

Using Bayesian Methodology to Estimate Liquefied Natural Gas Leak Frequencies

This analysis provides estimates on the leak frequencies of nine components found in liquefied natural gas (LNG) facilities. Data was taken from a variety of sources, with 25 different data sets included in the analysis. A hierarchical Bayesian model was used that assumes that the log leak frequency follows a normal distribution and the logarithm of the mean of this normal distribution is a linear function of the logarithm of the fractional leak area. This type of model uses uninformed prior distributions that are updated with applicable data.

PUBLICATION · Research Paper

Fire Safety of Hydrogen Leaks

Quenching limits of hydrogen diffusion flames on small burners were observed. Four burner types,
with diameters as small as 8 m, were considered: pinhole burners, curved-wall pinhole burners, tube
burners, and leaky fittings. In terms of mass flow rate, hydrogen had a lower quenching limit and a higher
blowoff limit than either methane or propane. Hydrogen flames at their quenching limits were the weakest

Disclaimer- The documents and references herein are for information purposes only and should not be construed as endorsement by the Hydrogen Safety Panel.