Skip to main content

Document library

PUBLICATION · Technical Report

HyRAM V1.1 User Guide

Hydrogen Risk Assessment Models (HyRAM) is a software toolkit that provides a basis for quantitative risk assessment and consequence modeling for hydrogen infrastructure and transportation systems. HyRAM integrates validated, analytical models of hydrogen behavior, statistics, and a standardized QRA approach to generate useful, repeatable data for the safety analysis of various hydrogen systems. HyRAM is a software developed by Sandia National Laboratories for the U.S. Department of Energy.

PUBLICATION · Research Paper

Ammonia and Hydrogen Vapor Cloud Explosion Testing (A Tale of Two Gases)

Ammonia and hydrogen represent opposite ends of the spectrum with regard to the potential blast loading resulting from an accidental vapor cloud explosion (VCE), although many in industry have expressed doubts as to whether either of these fuels actually pose a VCE hazard. Ammonia is some-times discounted as a VCE hazard due to the perceived difficulty in igniting an ammonia-air mixture and/or because of its low laminar burning velocity. Hydrogen is sometimes discounted as a VCE hazard due to the ease with which a hydrogen-air mixture can be ignited and/or because of its buoy-ancy.

PUBLICATION · Technical Report

Hydrogen Equipment Certification Guide: Listing, Labeling, and Approval Considerations

The purpose of this guide is to assist users of codes and standards that apply to hydrogen application and use in understanding and applying the approval, certification, listing, and labeling provisions of the codes and standards, in any application where the required certification, listing, and labeling of services, methods, or equipment has not yet been established or achieved.  

PUBLICATION · White Paper

Secondary Protection for 70 MPa Fueling 

In developing a 70 megapascal (MPa) fueling infrastructure, it is critical to ensure that a vehicle equipped with a lower service pressure fuel tank is never filled from a 70 MPa fueling source. Filling of a lower service pressure vehicle at a 70 MPa fueling source is likely to result in a catastrophic event with severe injuries or fatalities. The Hydrogen Safety Panel recommends that DOE undertake a two‐step process to address this issue.

PUBLICATION · Journal Article

PHYSICS AND MODELLING OF UNDER-EXPANDED JETS AND HYDROGEN DISPERSION IN ATMOSPHERE

The broad use of hydrogen as an energy carrier to tackle the issue of climate change is unavoidable. The emerging hydrogen economy poses new problems to be solved to ensure a level of safety in hydrogen technologies and infrastructure comparable to that for today’s fossil fuels. The pressure of onboard hydrogen storage in early-market

PUBLICATION · Research Paper

Fire Safety of Hydrogen Leaks

Quenching limits of hydrogen diffusion flames on small burners were observed. Four burner types,
with diameters as small as 8 m, were considered: pinhole burners, curved-wall pinhole burners, tube
burners, and leaky fittings. In terms of mass flow rate, hydrogen had a lower quenching limit and a higher
blowoff limit than either methane or propane. Hydrogen flames at their quenching limits were the weakest

Disclaimer- The documents and references herein are for information purposes only and should not be construed as endorsement by the Hydrogen Safety Panel.