Skip to main content

Document library

PUBLICATION · Technical Report

HyRAM V1.1 User Guide

Hydrogen Risk Assessment Models (HyRAM) is a software toolkit that provides a basis for quantitative risk assessment and consequence modeling for hydrogen infrastructure and transportation systems. HyRAM integrates validated, analytical models of hydrogen behavior, statistics, and a standardized QRA approach to generate useful, repeatable data for the safety analysis of various hydrogen systems. HyRAM is a software developed by Sandia National Laboratories for the U.S. Department of Energy.

PUBLICATION · Research Paper

Ammonia and Hydrogen Vapor Cloud Explosion Testing (A Tale of Two Gases)

Ammonia and hydrogen represent opposite ends of the spectrum with regard to the potential blast loading resulting from an accidental vapor cloud explosion (VCE), although many in industry have expressed doubts as to whether either of these fuels actually pose a VCE hazard. Ammonia is some-times discounted as a VCE hazard due to the perceived difficulty in igniting an ammonia-air mixture and/or because of its low laminar burning velocity. Hydrogen is sometimes discounted as a VCE hazard due to the ease with which a hydrogen-air mixture can be ignited and/or because of its buoy-ancy.

PUBLICATION · Technical Report

Hydrogen Equipment Certification Guide: Listing, Labeling, and Approval Considerations

The purpose of this guide is to assist users of codes and standards that apply to hydrogen application and use in understanding and applying the approval, certification, listing, and labeling provisions of the codes and standards, in any application where the required certification, listing, and labeling of services, methods, or equipment has not yet been established or achieved.  

PUBLICATION · Research Paper

Fire Safety of Hydrogen Leaks

Quenching limits of hydrogen diffusion flames on small burners were observed. Four burner types,
with diameters as small as 8 m, were considered: pinhole burners, curved-wall pinhole burners, tube
burners, and leaky fittings. In terms of mass flow rate, hydrogen had a lower quenching limit and a higher
blowoff limit than either methane or propane. Hydrogen flames at their quenching limits were the weakest

PUBLICATION · Technical Report

An Update to the Baker-Strehlow-Tang Vapor Cloud Explosion Prediction Methodology Flame Speed Test

The Baker-Strehlow-Tang vapor cloud explosion (VCE) blast load prediction methodology utilizes flame speed as a measure of explosion severity. In previous publications, guidance has been presented for selecting flame speeds as a function of congestion, confinement, and fuel reactivity. These recommended values were based on empirical data available from the literature.

Disclaimer- The documents and references herein are for information purposes only and should not be construed as endorsement by the Hydrogen Safety Panel.