Skip to main content

Document library

PUBLICATION · Journal Article

Reduced Order Models for Liquid Hydrogen Pooling and Vaporization Supported by Experiments

In the event of a leak of liquid hydrogen, a pool can form that vaporizes, disperses, and eventually dilutes to a non-flammable mixture. In this work, we describe fast-running models for the pooling and vaporization of liquid hydrogen in a steady cross-wind. Several pooling models from the literature are compared to solve for the flow and extent of the pool. The size of the pool can serve as the source for a separate dispersion model, which builds upon the existing one-dimensional Gaussian plume model in HyRAM+.

PUBLICATION · Technical Report

Reduced-Order Modeling of Hydrogen Releases from Vent Stacks and with Wind Effects

The physical release behavior of hydrogen is important to understand from a safety and design perspective. The consequences of unignited pressurized gaseous hydrogen plumes exiting vent stacks were considered by extending and modifying existing general hydrogen plume models. Entrainment, vent stack backpressure, and the flow regime of hydrogen exiting the vent were found to be significant factors affecting plume shape and size, but further investigation and validation with unchoked, low-Froude-number flows is recommended to improve the model’s robustness.

PUBLICATION · Technical Report

Assessment of Vibration and Shock Loading Environments on Steels Used in Railroad Applications Considering Hydrogen Embrittlement

Studies that examine the combined effects of hydrogen and rail loading environments in the context of hydrogen embrittlement of steels have not been performed. Large-scale hydrogen storage requires either gaseous hydrogen stored in pressure vessels and tubing or liquid hydrogen in cryogenic, insulated tanks. Since the focus of this study is on steels, we examine the influence of hydrogen on stainless steel used for high pressure tubing and cryogenic tanks and Cr-Mo steel liners used in gaseous pressure vessels.

PUBLICATION · Technical Report

Prioritizing Uncertainties in Hydrogen Contribution to Risk in Post-Crash Outcomes for Rail

This report presents analysis from Sandia National Laboratories predicting contributions to risk associated with the use of hydrogen technology for rail. Event sequence diagrams are used to describe possible accident scenarios and progressions. Initiating event frequencies and branch event probabilities for each scenario are quantified with uncertainty using distributions fit to Federal Railroad Administration and U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration data on applicable accidents from 2000 to 2020.

PUBLICATION · Technical Report

Audible Noise Modeling of Hydrogen Release Sonic Hazards in Rail Maintenance Facilities

This study implemented validated literature models to predict audible noise due to pressurized gaseous hydrogen releases through a thermally-activated pressure relief device (TPRD) and attached vent stack. A literature survey discovered limited hydrogen-specific noise prediction models validated by experiments. However, empirical noise prediction models for air flowing through pipes and valves were identified.

PUBLICATION · Research Paper

Integrity and Safety of Repurposed Hydrogen Pipelines in the European Union

The development of a comprehensive hydrogen infrastructure in the European Union is required to bridge the gap between hydrogen supply and demand. The repurposing of part of the existing natural gas infrastructure for the transport of hydrogen, in addition to new constructions, can accelerate the establishment of a hydrogen transmission network in the European Union. Hydrogen exposure is, however, known to notably reduce the ductility and fracture toughness of steel materials and increase fatigue crack growth rates.

PUBLICATION · Technical Report

Technical Justifications for Outdoor Bulk Gaseous Hydrogen Storage Setback Distances

Setback distances define a prescribed distance between a potentially hazardous system and different types of other systems, people, buildings, or materials that may be exposed to that hazard. Riskinformed separation distances are not meant to completely eliminate risk, but rather to limit the risk to an acceptable level. A sensitivity study of risk suggested that a leak size of 3% of the pipe cross-sectional area would be a conservative but reasonable basis.

PUBLICATION · White Paper

Lessons Learned and Best Practices for Compressed Hydrogen Transport Trailers

As demand for hydrogen increases, more hydrogen transport trailers and modules are being built and operated to supply fuel to the growing number of end uses. Concurrently, recent incidents involving these trailers have highlighted common factors that have contributed to fires and/or explosions.

PUBLICATION · Technical Report

Human Factors Considerations for Hydrogen Rail Refueling and Maintenance

The Federal Railroad Administration (FRA) contracted Sandia National Laboratories to review the risks introduced specifically through human interactions within hydrogen rail refueling and maintenance activities and present recommendations for future system development and implementation. Due to the lack of domestic hydrogen-powered trains at the time of review, observational data was collected on analogous existing systems to consider various ways hydrogen might be implemented within future designs.

PUBLICATION · Technical Report

Safety Standard for Hydrogen and Hydrogen Systems

This document and its companion document, Safety Standard for Oxygen and Oxygen Systems (NSS1740.151996),are identified as Tier 2 Standards and Technical Requirements in the NASA Safety and Documentation Tree (NHB 1700.1 1993). The information presented is intended as a reference to hydrogen design and practice and not as an authorizing document. The words "shall" and "must" are used in this document to indicate a mandatory requirement, and the authority for the requirement is given.

Disclaimer- The documents and references herein are for information purposes only and should not be construed as endorsement by the Hydrogen Safety Panel.