PUBLICATION · Progress Report
2014 Annual Progress Report
VIII.8 Hydrogen Safety Panel and Hydrogen Safety Knowledge Tools
PUBLICATION · Progress Report
VIII.8 Hydrogen Safety Panel and Hydrogen Safety Knowledge Tools
PUBLICATION · Presentation
Course Objectives
• Introduce the student to basic concepts in cryogenic
systems.
• Introduce the student to basic hardware used in
cryogenic systems and what the function of the
hardware is (i.e. why do you need that).
• Introduce the student to what may be experienced
during testing of cryogenic systems and what types of
measurements and instrumentation may be desired,
needed, or required.
• Introduce the student to various methods of modeling
and analysis of cryogenic systems including
strengths and weaknesses of various tools.
PUBLICATION · Journal Article
Owner/operators of chemical processing and petroleum refining sites often ask whether unconfined hydrogen vapor cloud explosions (VCEs) can actually occur. This question normally arises during the course of a consequence-based facility siting study (FSS) or a quantitative risk assessment (QRA). While it is generally recognized that a hydrogen release within a process enclosure could lead to an explosion, the potential for an external hydrogen release to cause a VCE is not as widely recognized and is often questioned.
PUBLICATION · Journal Article
AS THE WORLD SEEKS TO IDENTIFY alternative energy sources, hydrogen-powered fuel cells offer a broad range of benefits for the environment, the economy, and energy security. Hydrogen fuel cells have the potential to replace the internal combustion engine and to provide power in a wide range of stationary and portable applications.
PUBLICATION · Journal Article
It has been suggested that separation or safety distances for pressurised hydrogen storage can be reduced by the inclusion of walls or barriers between the hydrogen storage and vulnerable plant or other items. Various NFPA codes [1] suggest the use of 60 inclined fire barriers for protection against jet flames in preference to vertical ones. Work by Sandia National Laboratories [2] included experiments and modeling aimed at characterisation of the effectiveness of barrier walls at reducing hazards.
PUBLICATION · Technical Report
This document and its companion document, Safety Standard for Oxygen and Oxygen Systems (NSS1740.151996),are identified as Tier 2 Standards and Technical Requirements in the NASA Safety and Documentation Tree (NHB 1700.1 1993). The information presented is intended as a reference to hydrogen design and practice and not as an authorizing document. The words "shall" and "must" are used in this document to indicate a mandatory requirement, and the authority for the requirement is given.
We are the leaders in the building industries and factories. We're word wide. We never give up on the challenges.