Skip to main content

Document library

PUBLICATION · White Paper

Secondary Protection for 70 MPa Fueling 

In developing a 70 megapascal (MPa) fueling infrastructure, it is critical to ensure that a vehicle equipped with a lower service pressure fuel tank is never filled from a 70 MPa fueling source. Filling of a lower service pressure vehicle at a 70 MPa fueling source is likely to result in a catastrophic event with severe injuries or fatalities. The Hydrogen Safety Panel recommends that DOE undertake a two‐step process to address this issue.

PUBLICATION · Journal Article

PHYSICS AND MODELLING OF UNDER-EXPANDED JETS AND HYDROGEN DISPERSION IN ATMOSPHERE

The broad use of hydrogen as an energy carrier to tackle the issue of climate change is unavoidable. The emerging hydrogen economy poses new problems to be solved to ensure a level of safety in hydrogen technologies and infrastructure comparable to that for today’s fossil fuels. The pressure of onboard hydrogen storage in early-market

PUBLICATION · Technical Report

Safety Standard for Hydrogen and Hydrogen Systems

This document and its companion document, Safety Standard for Oxygen and Oxygen Systems (NSS1740.151996),are identified as Tier 2 Standards and Technical Requirements in the NASA Safety and Documentation Tree (NHB 1700.1 1993). The information presented is intended as a reference to hydrogen design and practice and not as an authorizing document. The words "shall" and "must" are used in this document to indicate a mandatory requirement, and the authority for the requirement is given.

Disclaimer- The documents and references herein are for information purposes only and should not be construed as endorsement by the Hydrogen Safety Panel.