Skip to main content

Document library

PUBLICATION · Technical Report

Hydrogen Plus Other Alternative Fuels Risk Assessment Models (HyRAM+) Version 5.1 Technical Reference Manual

The HyRAM+ software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen, natural gas, and autogas systems. HyRAM+ is designed to facilitate the use of state-of-the-art models to conduct robust, repeatable assessments of safety, hazards, and risk. HyRAM+ integrates deterministic and probabilistic models for quantifying leak sizes and rates, predicting physical effects, characterizing hazards (thermal effects from jet fires, overpressure effects from delayed ignition), and assessing impacts on people.

PUBLICATION · Technical Report

Safety of Mobile Hydrogen and Fuel Cell Technology Applications: An Investigation by the Hydrogen Safety Panel

Safe practices in the production, storage, distribution, and use of hydrogen are essential for the widespread acceptance of hydrogen and fuel cell technologies. A catastrophic failure in any hydrogen project could damage public perception of hydrogen and fuel cells. Given the nascent nature of the mobile hydrogen applications, incidents involving mobile equipment can have detrimental impacts for the public as well as stakeholders and project proponents who are committed to hydrogen’s use as a safe alternative energy resource. 

PUBLICATION · Engineering Design

Excess Flow Valves in Codes and Standards

Several codes require excess flow valves in pipelines so that in the case of line rupture, the flow will be shut off.   In theory, this is a good idea, however, in practicality, it has many limitations.  The sizing and practical uses make the sizing difficult if sometimes impossible, depending on the design parameters.   

PUBLICATION · Technical Report

LPG Component Leak Frequency Estimation

Liquefied petroleum gas (LPG) is used in heating, cooking, and as a vehicle fuel (called autogas). A safety risk assessment may be needed to assess potential hazard scenarios and inform the regulations, codes, and standards that apply to LPG facilities, such as autogas refueling facilities. The frequency of unintended releases in an LPG system is an important aspect of a system quantitative risk assessment. This report documents estimation of leakage frequencies for individual components of LPG systems.

PUBLICATION · Engineering Design

Discussion Points on HyTunnel CS Recommendation Report

The three-year HyTunnel CS project culminated in the report titled Deliverable D6.9, “Recommendations for inherently safer use of hydrogen vehicles in underground traffic systems.” The HyTunnel CS project aimed to perform pre-normative research for the safety of hydrogen-fueled vehicles traveling through tunnels or entering confined spaces. The main objective was to compare the relative risk of hydrogen vehicles entering underground traffic systems to existing fossil fuel-powered vehicles [1].

EVENT · Webinar

Gaseous Hydrogen Safety Considerations CHS Webinar Q&A

The information in this document provides answers to the questions that were raised during the Center for Hydrogen Safety April 27, 2023 webinar. The Q&As are sorted by topic with the question number for reference. The Q&As are sorted by topic with the question number for reference. Redundant questions were deleted from the original list.

PUBLICATION · Journal Article

Evaluation of Hydrogen Blend Stability in Low-Pressure Gas Distribution

Natural gas distribution companies are developing ambitious plans to decarbonize the services that they provide in an affordable manner and are accelerating plans for the strategic integration of renewable natural gas and the blending of green hydrogen produced by electrolysis, powered with renewable electricity being developed from large new commitments by states such as New York and Massachusetts. The demonstration and deployment of hydrogen blending have been proposed broadly at 20% of hydrogen by volume.

Disclaimer- The documents and references herein are for information purposes only and should not be construed as endorsement by the Hydrogen Safety Panel.