Skip to main content

Document library

PUBLICATION · Research Paper

Ammonia and Hydrogen Vapor Cloud Explosion Testing (A Tale of Two Gases)

Ammonia and hydrogen represent opposite ends of the spectrum with regard to the potential blast loading resulting from an accidental vapor cloud explosion (VCE), although many in industry have expressed doubts as to whether either of these fuels actually pose a VCE hazard. Ammonia is some-times discounted as a VCE hazard due to the perceived difficulty in igniting an ammonia-air mixture and/or because of its low laminar burning velocity. Hydrogen is sometimes discounted as a VCE hazard due to the ease with which a hydrogen-air mixture can be ignited and/or because of its buoy-ancy.

PUBLICATION · Research Paper

Fire Safety of Hydrogen Leaks

Quenching limits of hydrogen diffusion flames on small burners were observed. Four burner types,
with diameters as small as 8 m, were considered: pinhole burners, curved-wall pinhole burners, tube
burners, and leaky fittings. In terms of mass flow rate, hydrogen had a lower quenching limit and a higher
blowoff limit than either methane or propane. Hydrogen flames at their quenching limits were the weakest